TROUBLESHOOTING
PROBLEM
No steam is released through the hose or acces-
sories.
Drops of water leak from the attachments.
Dirty water is coming out.
Not enough steam pressure.
The steam is too wet.
Pressure is dropping during operation.
Machine is not heating.
The electrical cord is damaged.
POSSIBLE CAUSE
A.
Steam cleaner is not turned on.
B.
Water tank is empty.
C.
Unit is not plugged in.
D.
Boiler is not fully heated.
A.
Unit is not fully heated.
B.
Condensation was created from non-use.
C.
O-rings need to be replaced.
A.
Scale may have built up.
A.
The variable pressure control on the
steam cleaner may be set too low.
B.
Scale may have built up.
A.
There is too much water inside the boiler.
A.
Pressure set to max for too long.
A.
Out of water (light may not be on).
A.
Replace power cord.
REMEDY
A.
Follow the instructions on page 9.
B.
Put 700 ml (23 oz) of water into the boiler.
C.
Plug unit into outlet.
D.
Wait for the SteamReady™ indicator (6)
to turn on.
A.
Wait for the SteamReady™ indicator (6)
to turn on.
B.
Let water run through system until
steam comes out.
C.
Replace O-rings.
A.
Follow maintenance instructions
on page 17.
A.
Turn the variable pressure control wheel until
the desired pressure is reached.
B.
Follow maintenance instructions
on page 17.
A.
Let the steam come out until it is dry.
A.
Use lower pressure setting.
A.
Follow the "Refilling with water"
instructions on page 10.
A.
Contact Dupray at +44 333 011 2660