C/A ON/OFF ADAPTER
HELPFUL TIP:
Make sure to have the C02 / Compressed Air Tank filled before use.
•
Firmly, hand tighten the CO2 / Compressed Air Tank clockwise into the markers C/A On/Off
adapter.
•
Tighten the tank clockwise in the markers C/A On/Off adapter until it is snug. If an air leak occurs
between the tank and the C/A On/Off adapter, replace the urethane o-ring.
•
To pressurize the marker turn the adapter knob towards the ON position to pierce the pin valve on
the tank.
•
To release the pressure turn the dial knob towards the OFF position. This will release the pressure
in the hose line and stop the air flow in the marker.
IMPORTANT:
Markers that are equipped with regulators may store residual air after the C02/
Compressed Air Tank has been removed. To fully remove any residual air stored in the marker, turn the
C/A On/Off adapter knob counter-clockwise to shut off the air supplied from the tank. Take several dry
fire shots with the marker pointed in a safe direction until the marker has no remaining air.
IMPORTANT:
You should never need to use any hand tool to attach a Compressed Air Tank to the C/A
On/Off adapter.
NOTE:
O-rings in the markers parts kit are not supplied to attach with a C02/ Compressed Air Tank.
NOTE:
The hose line adapter supplied on the C/A On/Off is American thread 1/8" (NPT).
C/A ON/OFF Adapter
REGULATOR ADJUSTMENT
SCR026
WARNING:
Never at any time should you attempt to unscrew the Vertical Regulator while the marker is
pressurized. Doing so can cause serious injury or death.
The Electra w/Eye is equipped with the Fast Charge Inline Regulator that improves the markers
velocity consistency and air efficiency. Once the C02/ Compressed Air tank has been installed and
tank valve is opened by turning the C/A On/Off adapter knob clockwise, the marker is potentially
capable and ready to fire.
9
REG012
REG013