Parts of the energizer
Installation
Read all of the safety instructions in this manual and any
relevant government, regional and local safety standards
before installing the energizer.
Selecting a site for the installation
Follow these guidelines when selecting a site for your
installation.
Select a site where:
a good earth can be obtained
the energizer earth system will be at least 10 m (33')
from other earth systems (e.g. telephone, mains power
or the earth system of another energizer)
children and animals cannot interfere with the
installation
Make sure the energizer is installed:
adjacent to the electric fence
preferably in the middle of the electric fence system
close to a mains/line power outlet (if using a mains/line
supply to power the energizer)
at least 1 m (3') away from and not directly above the
battery (if using a battery to power the energizer)
If your installation is outdoors, also make sure that it is:
on firm ground away from flooding
inside a protective fence, if required.
Using the power adaptor and
battery leads
The energizer is supplied with a power adaptor (for
connection to mains/line power) and a set of battery leads
(for connection to a battery). Before connecting a power
adaptor or battery leads, ensure the energizer's selector
switch is set to Off
.
To use the power adaptor:
1
Connect the power adaptor to the Power input socket
on the rear of the energizer.
2
Connect the power adaptor to a suitable mains/line
power socket, ensuring there is 25 mm (1") of clear
space around the power adaptor.
To remove the power adaptor:
1
Disconnect the power adaptor from the mains/line
power.
2
Pull on the white connector to remove the power
adaptor plug from the Power input socket on the rear of
the energizer.
To use the battery leads:
1
Insert the battery lead into the Power input socket on
the rear of the energizer.
2
Connect the energizer to the battery using the battery
leads supplied. Attach the red clip to the positive (+)
terminal of the battery, and the black clip to its negative
(-) terminal.
Note:
If the energizer is to be used as part of a permanent
outdoor installation such as a solar installation, the battery
lead clips should be replaced by permanent battery
connectors.