SPECIFICATIONS
Model
Detection system
Passive infrared
When horizontal detection
Angle: 90°
Coverage
Detection distance: 40' (12m)
Horizontal zone: 7zones
Downward zone: 7zones
Horizontal: ±90°
Coverage adjustment
Detection distance: 6.6' ~ 40' (2m ~ 12m)
(By adjusting vertical angle of downward curtain)
Power supply
12 to 30V DC (non-polarity)
Current consumption
35mA MAX.
Dry contact relay output N.C./N.O. selectable
∗Contact capacity: 30V (AC/DC), 0.5A MAX. (Resistive load)
Alarm output
∗Contact operation: Detection time+off delay (2sec. -5min. approx)
Dry contact relay output N.C.
Tamper output
∗Contact capacity: 30V (AC/DC), 0.5A MAX. (Resistive load)
Red LED
Operation LED
Blinking at warming up (LED disabled)
Lighting at alarm (LED disabled)
Pulse count
1 / 3 (with a switch)
∗Approx. 30% (L)-Approx. 170% (H) (By Potentiometer)
Sensitivity adjustment
Detection mode
Connection
Terminals
Ambient temperature
−4°F to + 122°F (−20°C to + 50°C)
Mounting position
Indoor / Outdoor
Ingress protection
IP 54
Weight
13.7oz (390g)
Appearance
Body: AES resin
Wall mount attachment (BW-24)
Optional
Pole attachment (BP-22)
Solve possible problems according to the following table. If normal operations cannot be
TROUBLESHOOTING
restored by this means, contact either the dealer from whom you bought the unit or TAKEX.
Trouble
No power supply, broken wire or improper
voltage.
Cover shielded by substances (including
glass).
Improper area adjustment.
Completely inactive
Not yet 1minute after power turned on.
(Operation LED is fl ickering.)
No area covered by both upper and lower
sensor when set at AND mode. [Only
applicable to MS-12FE]
Improper area adjustment.
Cover face is soiled with dust or water drop.
Sometimes inactive
Area covered by both upper and lower sensor
is too small to be detected when set at AND
mode. [Only applicable to MS-12FE]
Unstable power voltage.
Something moving in protected area or too
rapid temperature variations.
Large electrical noise source such as power
machine nearby or its wiring close to that of
sensor.
Intense refl ection of sun light or head light
Activated when no person
shining on the sensor.
has passed
Refl ective lights such as sun light or head light
affect the downward zone.
Improper installment of the sensor.
Detection distance of the downward zone is
too long.
Cars or motor bikes located at the front of
detection area may activate the sensor.
Poor contact connection or broken wire or short
circuit.
The alarm LED lights,
but connected device is
Contact output is not working.
inactive
Is the connected device operation normal ?
MS-12TE
Angle: 90°×2
2sets of MS-12TE
sensors
40mA MAX.
AND/OR selectable
16.5oz (470g)
Lens: PE resin
Check
Correct power supply or replace broken wire.
Remove the substances.
Readjust the protection area setting.
Allow for warming up time (about 1min.)
Readjust the sensor angle so that the area to
be detected is covered by both upper and lower
sensor.
Readjust the protection area setting.
Clean the cover with soft cloth.
Readjust the sensor angle.
Stabilize the power voltage.
Remove the cause.
Relocate the device.
Relocate the device. Readjust the protection
area setting.
Remove refl ective objects.
Readjust the protection area setting.
Install the sensor parallel.
Readjust the detection distance.
Readjust the area setting and range adjustment
so that there is no such undesirable detections.
Check the wiring or connection.
Check the contact output terminal using a
tester.
Check the connected device.
Limited Warranty:
MS-12FE
TAKEX products are warranted to be free from
defects in material and workmanship for 12 months
from original date of shipment. Our warranty does
not cover damage or failure caused by Acts of God
(including inductive surge by lightning), abuse,
misuse, abnormal usage, faulty installation, improper
maintenance or any repairs other than those
provided by TAKEX. All implied warranties with
respect to TAKEX, including implied warranties for
merchantability and implied warranties for fi tness,
are limited in duration to 12 months from original date
of shipment. During the Warranty Period, TAKEX
will repair or replace, at its sole option, free of charge,
any defective parts returned prepaid. Please provide
the model number of the products, original date of
shipment and nature of diffi culty being experienced.
There will be charges rendered for product repairs
made after our Warranty period has expired.
Corrective Action