Pout (dBuV )
106
104
102
100
98
96
34.4 36.2 37.9 39.5 41.0 42.4 43.7 45.0
94
32.4 34.2 35.9 37.5 39.0 40.4 41.7 43.0 44.1
92
30.4 32.2 33.9 35.5 37.0 38.4 39.7 41.0 42.1 43.2
90
30.2 31.9 33.5 35.0 36.4 37.7 39.0 40.1 41.2 42.1
88
29.9 31.5 33.0 34.4 35.7 37.0 38.1 39.2 40.1 41.0
86
29.5 31.0 32.4 33.7 35.0 36.1 37.2 38.1 39.0 39.8
84
29.0 30.4 31.7 33.0 34.1 35.2 36.1 37.0 37.8 38.5
82
28.4 29.7 31.0 32.1 33.2 34.1 35.0 35.8 36.5 37.1
80
27.7 29.0 30.1 31.2 32.1 33.0 33.8 34.5 35.1 35.6
78
27.0 28.1 29.2 30.1 31.0 31.8 32.5 33.1 33.6 34.0
26.1 27.2 28.1 29.0 29.8 30.5 31.1 31.6 32.0 32.4
76
25.2 26.1 27.0 27.8 28.5 29.1 29.6 30.0 30.4 30.6
74
72
24.1 25.0 25.8 26.5 27.1 27.6 28.0 28.4 28.6
70
23.0 23.8 24.5 25.1 25.6 26.0 26.4 26.6
68
21.8 22.5 23.1 23.6 24.0 24.4 24.6
66
20.5 21.1 21.6 22.0 22.4 22.6
64
19.1 19.6 20.0 20.4 20.6
62
17.6 18.0 18.4 18.6
60
16.0 16.4 16.6
58
14.4 14.6
56
12.6
94
96
98
126
80
50
Tableau 2 – lecture CNR signaux numériques satellites
Pout (dBuV )
106
104
102
100
98
96
49.7 50.8 51.8 52.8 53.7 54.6 55.4 56.2
47.7 48.8 49.8 50.8 51.7 52.6 53.4 54.2 54.9
94
92
45.7 46.8 47.8 48.8 49.7 50.6 51.4 52.2 52.9 53.5
90
44.8 45.8 46.8 47.7 48.6 49.4 50.2 50.9 51.5 52.1
88
43.8 44.8 45.7 46.6 47.4 48.2 48.9 49.5 50.1 50.6
42.8 43.7 44.6 45.4 46.2 46.9 47.5 48.1 48.6 49.1
86
84
41.7 42.6 43.4 44.2 44.9 45.5 46.1 46.6 47.1 47.5
82
40.6 41.4 42.2 42.9 43.5 44.1 44.6 45.1 45.5 45.9
80
39.4 40.2 40.9 41.5 42.1 42.6 43.1 43.5 43.9 44.2
38.2 38.9 39.5 40.1 40.6 41.1 41.5 41.9 42.2 42.5
78
76
36.9 37.5 38.1 38.6 39.1 39.5 39.9 40.2 40.5 40.7
74
35.5 36.1 36.6 37.1 37.5 37.9 38.2 38.5 38.7 38.8
72
34.1 34.6 35.1 35.5 35.9 36.2 36.5 36.7 36.8
32.6 33.1 33.5 33.9 34.2 34.5 34.7 34.8
70
68
31.1 31.5 31.9 32.2 32.5 32.7 32.8
66
29.5 29.9 30.2 30.5 30.7 30.8
64
27.9 28.2 28.5 28.7 28.8
26.2 26.5 26.7 26.8
62
60
24.5 24.7 24.8
58
22.7 22.8
56
20.8
94
96
98
126
80
50
Tableau 3 – lecture CNR signaux numériques terrestres DTT
44.4 46.2 47.9
42.4 44.2 45.9 47.5
40.4 42.2 43.9 45.5 47.0
38.4 40.2 41.9 43.5 45.0 46.4
36.4 38.2 39.9 41.5 43.0 44.4 45.7
100 102 104 106 108 110 112 Pin (dBuV )
32
20
13
8
5
3
59.7 60.8 61.8
57.7 58.8 59.8 60.8
55.7 56.8 57.8 58.8 59.7
53.7 54.8 55.8 56.8 57.7 58.6
51.7 52.8 53.8 54.8 55.7 56.6 57.4
100 102 104 106 108 110 112 Pin (dBuV )
32
20
13
8
5
28
Opt. Att. (dB)
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
2
Channels
Opt. Att. (dB)
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
3
2
Channels

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Opt-rx51

Table des Matières