4. GENERAL SPECIFICATIONS
Input: K sensors only.
Output: 1 mV .../ °C or °F.
Measurement range: -40°C to 1000°C / -40°C to 1800°F.
NB 1: The measurement range is determined by the sensor used.
For example, with the SK6 sensor, the measurement range
of the adapter is -40°C to +285°C.
NB 2: The accuracy class of the K sensors may be 1, 2 or 3.
Impedance of the associated multimeter: Z > 2 MΩ.
Power supply:
One 9V battery.
Charge life: 300 hours with alkaline battery (6 FL 22).
150 hours with saline battery (6 F 22).
Battery charge indication: «LOW BATT» LED on.
Climatic conditions:
Use:
temperature: 0°C to +50°C.
temperature coefficient: 0.1 x (specified accuracy) per °C for
an ambient temperature < 18°C or > 28°C.
relative humidity: < 70% RH.
altitude: up to 2,000 m.
Storage:
temperature: -20°C to +60°C (without battery).
relative humidity: < 90% RH.
Electrical safety (according to NF EN 61010-1.A2.Ed95):
Installation category II
Electromagnetic compatibility:
Emission (EN 61326-1 Ed. 98)
Immunity (EN50082-1 Ed. 97 and EN 61326-1 Ed. 98)
Immunity AM em. (EN 61326-1.B Ed. 98)
Mechanical protection:
Protection level: IP 40 (according to I.E.C. 529 Ed. 89).
Dimensions / Weight: 120 x 64 x 35 mm / 200 g.
5. TO ORDER
C.A 801 adapter with 1 K sensor ........................ P01.6524.01 Z
C.A 803 adapter with 2 K sensors ...................... P01.6524.11 Z
Delivered with K sensor(s), one 9 V battery and this user's manual.
Accessories and spare parts
SK6 flexible sensor (-40°C to 285°C) ................... P03.6529.06
SK11 needle sensor (-40°C to 600°C) ................. P03.6529.17
SK13 general-purpose sensor
(-40°C to 1000°C) ................................................ P03.6529.18
SK14 surface sensor / elbowed
(-40°C to 450°C) .................................................. P03.6529.19
SK15 surface sensor / spring (-40°C to 900°C) ... P03.6529.20
SK17 air sensor (-40°C to 600°C) ........................ P03.6529.21
SK19 surface sensor / magnet (-20°C to 200°C) . P03.6529.22
PK9 retractable needle sensor (250°C) ............... P03.6529.15
PP1 handle .......................................................... P03.6529.12
CK3 extension ..................................................... P03.6529.13
Carrying bag ........................................................ P01.2980.48