Maintenance
Unplug the appliance before carrying out
any maintenance operation.
Warning
This appliance contains hydrocarbons in its
cooling unit maintenance and recharging
must therefore only be carried out by
authorised technicians.
Defrosting
Frost is automatically eliminated from the evaporator
of the refrigerator compartment every time the motor
compressor stops, during normal use.
The defrost water drains out through a trough into a
special container at the back of the appliance, over
the motor compressor, where it evaporates.
It is important to periodically clean the defrost
water drain hole (F) situated under the salad
drawers to prevent the water overflowing and
dripping onto the food inside. Use the special
cleaner provided (P), which you will find already
inserted into the drain hole.
S.I.011
Periodic cleaning
Never use metal objects for clearing your
appliance as it may get damaged.
Clean the inside with warm water and bicarbonate of
soda. Rinse and dry thoroughly.
The appliance is equipped with a ventilation grid.
Keep clean to guarantee good ventilation and good
working order of the appliance.
An accumulation of dust will affect the performance
of the appliance and cause excessive electricity
consumption.
P
F
The structure of the appliance permits cleaning of the
rear zone close to the wall, using a vacuum cleaner.
1. Remove the plinth (1), then the ventilation grid (2);
2. Carefully pull the air deflector out (3), checking
that there is no water left from the defrosting.
S.I.013
Periods of non-operation
When the appliance is not in use for long periods,
take the following precautions:
• remove the plug from the wall socket;
• remove all food:
• defrost and clean the interior and all accessories;
• leave the door ajar to allow air to circulate to
prevent unpleasant smells.
Interior light
The light bulb inside the refrigerator compartment
can be reached as follows:
1. unscrew the light cover securing screws;
2. unhook the moving part by pressing it as shown in
the figure.
D411
If the door is open and the light does not come on,
check that the bulb is properly screwed in; if it still
does not work, replace the bulb with one of the same
power.
The maximum rating is shown on the light cover.