EXTENSION CORDS

Double insulated equipment can use either a two or three wire extension cord. As the distance from the
power supply outlet increases, you must use a heavier gauge extension cord. Using extension cords
with inadequately sized wire causes a serious drop in voltage, resulting in loss of power and possible
tool damage. Refer to the table shown below to determine the required minimum wire size.
Guidelines for Using Extension Cords
• If you are using an extension cord outdoors, be sure it is marked with the suffi x "W-A" ("W" in Canada)
to indicate that it is acceptable for outdoor use.
• Be sure your extension cord is properly wired and in good electrical condition. Always replace a
damaged extension cord or have it repaired by a qualifi ed person before using it.
• Protect your extension cords from sharp objects, excessive heat, and damp or wet areas.
Recommended Minimum Wire Gauge for Extension Cords (120 Volt)
Nameplate
Extension Cord Length
Amperes
25 Feet
(At Full Load)
0–2.0
2.1–3.4
3.5–5.0
5.1–7.0
7.1–12.0
12.1–16.0
16.1–20.0
DOUBLE-INSULATED INSTRUCTIONS
WARNING:
are provided instead of grounding. No means of grounding is provided on a double-
insulated appliance, nor should a means for grounding be added. Servicing a double-
insulated Vacuum requires extreme care and knowledge of the system, and should be
done only by qualifi ed service personnel. Replacement parts for a double-insulated
Vacuum must be identical to the parts they replace. Your double-insulated Vacuum is
marked with the words "DOUBLE INSULATED" and the symbol
(square within a square) may also be marked on the appliance.

POLARIZED PLUG

Double insulated products are equipped with a polarized plug (one blade is
wider than the other). This plug will fi t in a polarized outlet only one way. If the plug does not
fi t fully in the outlet, reverse the plug. If it still does not fi t, contact a qualifi ed electrician to
install a polarized outlet. Do not change the plug in any way. Double insulation eliminates the
need for the three wire grounded power cord and grounded power supply system.
SAVE THESE INSTRUCTIONS
50 Feet
18
18
18
18
18
18
18
16
18
14
14
12
12
10
In a double-insulated vacuum, two systems of insulation
English
75 Feet
100 Feet
18
18
18
16
16
14
14
12
12
10
10
10
8
8
4
150 Feet
200 Feet
16
16
14
14
12
12
12
10
8
8
8
6
6
6