FLOOR PROTECTOR
When the heater is used on a combustible floor, use an Underwriters Listed floor protector that conforms to UL
Standards (UL 1618) and CAN/ULC for Canada, that provides at minimum type 1 ember protection. The floor
protector should be under the stove, 16" (18" for Canadian Instillations)beyond the front and 8" beyond each
side of the fuel loading and ash removal opening. If there is a horizontal section of chimney connector, the floor
protector should go under it and 2 inches beyond each side
The floor protector should exceed the stove as follows:
2"
(21mm)
2"
(21mm)
U.S. 52"
(1321mm)
CAN. 60"
(1524mm)
Protecteur
de plancher
(305mm)
(204mm)
NON-COMBUSTIBLE CONSTRUCTION
IN ACCORDANCE WITH NFPA 211
AND CAN/CSA-B365-M91
12
NOTE: DASHED LINES SHOW
41.5"
STRAIGHTUP AND DOWN THROUGH
(1055mm)
THE WALL INSTALLATION.
*CANADIAN INSTALLATIONS REQUIRE
A MINIMUM OF 18" (450mm) ON THE
FUEL LOADING SIDE AND 8"(203mm)
8"
INCHES (METRIC)
ON ALL OTHER SIDES.
7