BLOWER ASSEMBLY-OPTIONAL
INSTALLATION
1. Remove the Panel (A) using tin snips or knock out using
a hammer and chisel careful not to distort the mounting
surface.
2. Attach the Blower Mounting Box (B) to the rear of the
unit using four(4) of the supplied #10 screws.
3. Then mount the Blower Assembly with the four(4)
remaining screws.
OPERATION
1. Rotating the rheostat control knob clockwise will turn
ON the blower.
2. When turned on, the blower comes on HIGH, then as the
knob is rotated clockwise, the blower speed reduces.
3. Rotate the knob counter-clockwise to turn OFF.
Caution! Route the Power Supply Cord away from the heat source
and out of high traffic areas.
CABINET DOOR KNOB ASSEMBLY
The cabinet door knob is mounted on the inside of the cabinet door
to facilitate shipping and must be removed and re-installed for proper
usage.
To get the cabinet door open, place your hand under the cabinet
frame (right hand side of the cabinet door) and push door out.
FOLLOW THESE INSTRUCTIONS FOR DOOR KNOB ASSEMBLY:
1. Remove the machine screw and the door knob.
2. Place the knob on the outside of the cabinet door, re-install the
machine screw and tighten being careful not to strip out the
threads in the plastic handle.
NOTE: During opening and closing of the feed and ash doors of this heater, it may seem that the fit of the
door is "too tight". As the heater is fired, the gasketing "settles" or "seats" itself in the door. The tight fit at the
factory and before the heater's initial firing is to insure a good seal after the gasketing "settles".
4
ASSEMBLY INSTRUCTIONS
A
B
MACHINE SCREW
CABINET DOOR KNOB
C
D