Recommended Vent Length
A 3¹⁄
" x 10" (8.3 cm x 25.4 cm) rectangular or 6" (15.2 cm) round
4
vent should be used.
The total length of the vent system including straight vent,
elbow(s), transitions, and wall or roof caps must not exceed
the equivalent of 140 ft (42.7 m) for either type of vent. See
the "Recommended Standard Fittings" section for equivalent
lengths.
For best performance, use no more than three 90° elbows.
To calculate the length of the system you need, add the
equivalent lengths of each vent piece used in the system.
See the following examples.
3¹⁄
" x 10" (8.3 x 25.4 cm) vent system = 73 ft (22.2 m) total.
4
A
2 ft
(0.6 m)
A. One 3¹⁄
" x 10" (8.3 x 25.4 cm) 90° elbow = 25 ft (7.6 m)
4
B. 1 wall cap = 40 ft (12.2 m)
C. 2 ft (0.6 m) + 6 ft (1.8 m) straight = 8 ft (2.4 m)
Call your authorized dealer or service center. When you call, you will need the microwave oven model number and serial number. Both
numbers can be found on the model and serial number plate, which is located behind the microwave oven door on the front frame of
the microwave oven.
If you need additional assistance, call us at our toll-free number or visit our website listed in the User Guide.
If any of the installation hardware needs to be replaced, call us at our toll-free number listed in the User Guide.
Following is a list of available replacement parts. You will need your model number located on the front facing of the microwave oven
opening, behind the door.
Damper assembly
Mounting plate
Mounting Screw Kit (includes parts A through G in "Parts Supplied" in the "Tools and Parts" section)
B
6 ft (1.8 m)
C

ASSISTANCE

Replacement Parts

6" (15.2 cm) vent system = 73 ft (22.2 m) total.
A
2 ft
(0.6 m)
C
A. Two 90° elbows = 20 ft (6.1 m)
B. 1 wall cap = 40 ft (12.2 m)
C. 1 rectangular-to-round transition piece = 5 ft (1.5 m)
D. 2 ft (0.6 m) + 6 ft (1.8 m) straight = 8 ft (2.4 m)
If the existing vent is round, a rectangular-to-round transition
piece must be used. In addition, a rectangular 3" (7.6 cm)
extension vent between the damper assembly and rectangular to
round transition piece must be installed to keep the damper from
sticking.