MICROWAVE HOOD COMBINATION
This product is suitable for use above electric or gas cooking products up to 36" (91.4 cm) wide.
These installation instructions cover different models. The appearance of your particular model may differ slightly from the
illustration in these installation instructions.
DE L'ENSEMBLE FOUR À MICRO-ONDES/HOTTE
Ce produit est conçu pour l'utilisation au-dessus d'appareils de cuisson électriques ou à gaz de 36" (91,4 cm) de largeur
ou moins.
Ces instructions d'installation sont valables pour plusieurs modèles. Il se peut que l'apparence de votre propre modèle soit
légèrement différente de celle montrée sur les illustrations dans ce document.
MICROWAVE HOOD COMBINATION SAFETY.....................2
INSTALLATION REQUIREMENTS..........................................2
Tools and Parts .....................................................................2
Location Requirements .........................................................3
Product Dimensions..............................................................3
Electrical Requirements ........................................................4
INSTALLATION INSTRUCTIONS............................................4
Remove Mounting Plate........................................................4
Rotate Blower Motor.............................................................4
Locate Wall Stud(s) ...............................................................6
Mark Rear Wall ......................................................................7
Drill Holes in Rear Wall..........................................................7
Attach Mounting Plate to Wall ..............................................8
Prepare Upper Cabinet .........................................................8
Install Damper Assembly ......................................................9
Install the Microwave Oven...................................................9
Complete Installation ..........................................................10
VENTING DESIGN SPECIFICATIONS ..................................11
ASSISTANCE..........................................................................12
Replacement Parts..............................................................12
Accessories .........................................................................12
8206588
INSTALLATION INSTRUCTIONS
INSTRUCTIONS D'INSTALLATION
Table of Contents / Table des matières
EXIGENCES D'INSTALLATION.........................................................13
Outillage et pièces...........................................................................13
Exigences d'emplacement..............................................................14
Dimensions du produit ....................................................................14
Spécifications électriques ...............................................................15
INSTRUCTIONS D'INSTALLATION ..................................................15
Dépose de la plaque de montage...................................................15
Réorientation du moteur du ventilateur ..........................................15
Tracé sur le mur arrière ...................................................................18
Perçage de trous dans le mur arrière..............................................18
Fixation de la plaque de montage sur le mur .................................19
Préparation du placard mural..........................................................20
Installation du module du clapet anti-reflux....................................20
Installation du four à micro-ondes ..................................................21
Achever l'installation........................................................................22
ASSISTANCE ......................................................................................24
Pièces de rechange.........................................................................24
Accessoires .....................................................................................24

Publicité

Table des Matières
loading

Sommaire des Matières pour Whirlpool YMH1170XSS0

  • Page 1: Table Des Matières

    MICROWAVE HOOD COMBINATION INSTALLATION INSTRUCTIONS This product is suitable for use above electric or gas cooking products up to 36" (91.4 cm) wide. These installation instructions cover different models. The appearance of your particular model may differ slightly from the illustration in these installation instructions.
  • Page 2: Microwave Hood Combination Safety

    MICROWAVE HOOD COMBINATION SAFETY Your safety and the safety of others are very important. We have provided many important safety messages in this manual and on your appliance. Always read and obey all safety messages. This is the safety alert symbol. This symbol alerts you to potential hazards that can kill or hurt you and others.
  • Page 3: Location Requirements

    Installation Dimensions Location Requirements NOTE: The grounded 3 prong outlet must be inside the upper cabinet. See “Electrical Requirements” section. Check the opening where the microwave oven will be installed. The location must provide: Minimum installation dimensions. See “Installation Dimensions” illustration. Minimum one 2"...
  • Page 4: Electrical Requirements

    Electrical Requirements Recommended: WARNING A time-delay fuse or time-delay circuit breaker. A separate circuit serving only this microwave oven. GROUNDING INSTRUCTIONS For all cord connected appliances: The microwave oven must be grounded. In the event of an electrical short circuit, grounding reduces the risk of Electrical Shock Hazard electric shock by providing an escape wire for the electric Plug into a grounded 3 prong outlet.
  • Page 5 3. Remove 2 screws attaching blower motor to back of microwave oven. Roof Venting Installation Only 1. Repeat Step 1 from “Wall Venting Installation Only.” 2. Repeat Step 2 from “Wall Venting Installation Only.” 3. Repeat Step 3 from “Wall Venting Installation Only.” 4.
  • Page 6: Locate Wall Stud(S)

    Locate Wall Stud(s) NOTE: If no wall studs exist within the cabinet opening, do not 1. Using a stud finder, locate the edges of the wall stud(s) within install the microwave oven. the opening. See illustrations in “Possible Wall Stud Configurations.” 2.
  • Page 7: Mark Rear Wall

    Wall Venting Installation Only Mark Rear Wall The microwave oven must be installed on a minimum of 1 wall stud, preferably 2, using a minimum of 1 lag screw, preferably 2. Centerline Upper cabinet bottom 1. Using measuring tape, find and clearly mark the vertical centerline of the opening.
  • Page 8: Attach Mounting Plate To Wall

    Wall Stud at One Corner Hole (Figure 3) Attach Mounting Plate to Wall NOTE: Secure the mounting plate to the wall at both bottom 1. With the support tabs of the mounting plate facing forward, corner holes drilled into the wall studs and/or drywall using either insert a 1/4-20 x 3"...
  • Page 9: Install Damper Assembly

    5. Cut the 1¹⁄₂" (3.8 cm) diameter hole at the circular shaded area “G” on the template. This hole is for the power supply cord. Install the Microwave Oven NOTE: If upper cabinet is metal, the supply cord bushing needs to be installed around the supply cord hole, as shown.
  • Page 10: Complete Installation

    NOTE: If microwave oven does not need to be adjusted, skip 2. Connect vent to damper assembly. steps 7-9. 7. If adjustment is required, rotate microwave oven downward. Using 2 or more people, lift microwave oven off of mounting plate, and set aside on a protected surface. 8.
  • Page 11: Venting Design Specifications

    VENTING DESIGN SPECIFICATIONS This section is intended for architectural designer and builder/ Rectangular to Round Transition contractor reference only. NOTE: The minimum 3" (7.6 cm) clearance must exist between NOTES: the top of the microwave oven and the rectangular to round transition piece so that the damper can open freely and fully.
  • Page 12: Assistance

    Recommended Vent Length ASSISTANCE A 3¹⁄₄ x 10 (8.3 x 25.4 cm) rectangular or 6 (15.2 cm) round vent " " " Call your authorized dealer or service center. When you call, you should be used. will need the microwave oven model number and serial number. The total length of the vent system including straight vent, Both numbers can be found on the model and serial number elbow(s), transitions and wall or roof caps must not exceed the...
  • Page 13: Sécurité De L'ensemble Four À Micro-Ondes/Hotte

    SÉCURITÉ DE L’ENSEMBLE FOUR À MICRO-ONDES/HOTTE Votre sécurité et celle des autres est très importante. Nous donnons de nombreux messages de sécurité importants dans ce manuel et sur votre appareil ménager. Assurez-vous de toujours lire tous les messages de sécurité et de vous y conformer. Voici le symbole d’alerte de sécurité.
  • Page 14: Exigences D'emplacement

    Dimensions à respecter lors de l'installation Exigences d'emplacement REMARQUE : La prise de courant à 3 alvéoles reliée à la terre doit être située à l'intérieur du placard mural. Voir la section Inspecter l'espace où le four à micro-ondes sera installé. “Spécifications électriques”.
  • Page 15: Spécifications Électriques

    Spécifications électriques AVERTISSEMENT INSTRUCTIONS DE LIAISON À LA TERRE Pour tout appareil ménager connecté par un cordon de courant électrique : Il faut que le four à micro-ondes soit relié à la terre. En cas de court-circuit électrique, la liaison à la terre réduit le risque de choc électrique car le courant électrique dispose d’un itinéraire direct d’acheminement à...
  • Page 16 2. Conserver ensemble la plaque de support du clapet et la vis. Pour une installation avec décharge à l'extérieur à 3. Retirer deux vis fixant le moteur du ventilateur à l'arrière du travers le toit seulement four à micro-ondes. 1. Répéter l'étape 1 de “Pour une installation avec décharge murale seulement”.
  • Page 17: Identifier La Position Du/Des Poteaux Du Colombage Mural

    Identifier la position du/des poteaux du colombage mural REMARQUE : S'il n'y a aucun poteau du colombage dans la zone 1. Utiliser un détecteur magnétique de clou/vis pour localiser délimitée par l'ouverture dans le placard mural, ne pas installer le dans l'ouverture les rives des poteaux du colombage mural.
  • Page 18: Tracé Sur Le Mur Arrière

    Pour une installation avec décharge murale seulement Tracé sur le mur arrière Le four à micro-ondes doit être fixé sur au moins un poteau du colombage mural, et de préférence sur 2 poteaux; on utilise pour Axe central Fond du placard mural cela au moins 1 vis d'ancrage, et de préférence 2 vis ou plus.
  • Page 19: Fixation De La Plaque De Montage Sur Le Mur

    4. Pousser les vis avec écrou articulé à travers le panneau de Un trou d’angle face à un poteau du colombage mural gypse; visser les vis à la main pour vérifier que chaque écrou articulé s'est déployé et prend appui contre le panneau de (Figure 3) gypse.
  • Page 20: Préparation Du Placard Mural

    Préparation du placard mural Installation du module du clapet anti-reflux 1. Interrompre l'alimentation électrique. 2. Retirer tout le contenu du placard mural. (pour décharge à travers le mur uniquement) 3. Placer le gabarit “placard mural” contre le fond du placard 1.
  • Page 21: Installation Du Four À Micro-Ondes

    Installation du four à micro-ondes 4. Alors que l'avant du four à micro-ondes est encore incliné, AVERTISSEMENT enfiler le cordon d'alimentation à travers le trou de passage percé dans le fond du placard mural. Risque du poids excessif Utiliser deux ou plus de personnes pour déplacer et installer le four à...
  • Page 22: Achever L'installation

    Pour une installation avec décharge à l'extérieur à Achever l'installation travers le toit seulement 1. Pour l'installation des filtres sur l'appareil, voir le Guide d'utilisation et d'entretien. 1. Insérer le module du clapet anti-reflux à travers l'ouverture découpée dans le placard, de telle manière que la patte longue du module du clapet anti-reflux puisse glisser sous les AVERTISSEMENT pattes d'arrimage relevées de la plaque de support du clapet.
  • Page 23: Spécifications/Conception Du Circuit D'évacuation

    SPÉCIFICATIONS/CONCEPTION DU CIRCUIT D'ÉVACUATION Cette section présente de l'information de référence uniquement, à l'intention des architectes/concepteurs et constructeurs. REMARQUES : Raccord de transition rectangulaire/rond Les matériaux du circuit d'évacuation nécessaires à REMARQUE : On doit disposer d'un espace libre de 3" (7,6 cm) l’installation ne sont pas fournis avec l'ensemble four à...
  • Page 24: Longueur Recommandée Du Circuit D'évacuation

    Longueur recommandée du circuit d'évacuation ASSISTANCE On devrait utiliser un conduit rectangulaire 3¼" x 10" (8,3 x Appeler le marchand local autorisé ou le centre de service agréé. 25,4 cm), ou un conduit rond de dia. 6" (15,2 cm). Lors de l'appel, vous aurez besoin des numéros de modèle et de La longueur équivalente totale du circuit d'évacuation, ceci série du four à...

Ce manuel est également adapté pour:

Imh16xsq0Ymh1160xsq0

Table des Matières