Introduction

Always consult your local Building Department regarding regula-
tions, codes or ordinances which apply to the installation of a di-
rect vent wall furnace.
Instructions to Installer.
1. Installer must leave instruction manual with owner after instal-
lation.
2. Installer must have owner fill out and mail warranty card sup-
plied with furnace.
3. Installer should show owner how to start and operate furnace
and thermostat.
Warning:
Any change to this furnace or its control can be dangerous.
This is a heating appliance and any panel, door, or guard
removed for servicing an appliance must be replaced prior
to operating the appliance.
To Conserve Gas: Turn off pilot when heater is not in use.
General Information
This furnace is design certified in accordance with American
National Standard/CSA Standard Z21.86b-2002 and CSA 2.32b-
2002 by the Canadian Standards Association, as a fan type direct
vent wall furnace to be installed according to these instructions.
Any alteration of the original design, installed other than as
shown in these instructions or use with a type of gas not
shown on the rating plate is the responsibility of the person
and company making the change.
Important
All correspondence should refer to complete Model No., Serial
No., and type of gas.
Notice: During initial firing of this unit, its paint will bake out and
smoke will occur. To prevent triggering of smoke alarms, ventilate
the room in which the unit is installed.
Installation on Rugs and Tile
If this appliance is installed directly on carpeting, tile or other
combustible material other than wood flooring, the appliance shall
be installed on a metal or wood panel extending the full width and
depth of the appliance.
The base referred to above does not mean the fire-proof base as
used on wood stoves. The protection is for rugs that are extremely
thick and light colored tile.
Installation in Residential Garages
Gas utilization equipment in residential garages shall be installed
Model
Input BTU/HR
Height
Width
Depth
Gas Inlet
CFM

Accessories

SOR-1
SOK-1
*DV-822
*DV-822, Vinyl siding vent kit, adds 3" to wall depth. You must include the three (3) additional inches for TOTAL wall depth when
ordering a vent kit.
Page 6
INTRODUCTION
so that all burners and burner ignition devices are located not less
than 18" above the floor.
Such equipment shall be located, or protected, so it is not subject
to physical damage by a moving vehicle.
Qualified Installing Agency
Installation and replacement of gas piping, gas utilization equip-
ment or accessories and repair and servicing of equipment shall
be performed only by a qualified agency. The term "qualified agen-
cy" means any individual, firm, corporation or company which ei-
ther in person or through a representative is engaged in and is
responsible for (a) the installation or replacement of gas piping or
(b) the connection, installation, repair or servicing of equipment,
who is experienced in such work, familiar with all precautions re-
quired and has complied with all the requirements of the authority
having jurisdiction.
State of Massachusetts: The installation must be made by a
licensed plumber or gas fitter in the Commonwealth of Mas-
sachusetts.
The installation must conform with local codes or, in the absence of
local codes, with the National Fuel Gas Code ANSI Z223.1/NFPA
54* Natural Gas and Propane Installation Code, CSA B149.1.
* Available from the American National Standards Institute, Inc., 11
West 42nd St., New York, N.Y. 10036
High Altitudes
For altitudes/elevations above 2,000 feet, input ratings should be
reduced at the rate of 4 percent for each 1,000 feet above sea
level. For Canadian high altitude applications, this appliance is
suitable for installation at elevations between 0 feet and 4,500 feet
without change.
Piezo Pilot Ignitor Instructions
Depressing the red button completely causes a spark to occur at
the pilot. This is a substitute for a match which requires opening
the pilot hole cover.
To light the pilot, it is important that the electrode be 1/8" from the
thermocouple. The spark must occur at the point the burner flame
hits the thermocouple. The end of the electrode will be red hot with
the pilot on.
On a new installation with air in the gas line, it is suggested that a
match be used. The match will light the pilot faster than the piezo
under this condition.

SPECIFICATIONS

DVC-35SPP
35,000
72 1/2"
14 1/8"
10 3/8"
1/2" Pipe
275
Register, Side Outlet
Side Outlet Kit, 10" (25.4cm) Boot Assembly with Register
Vinyl Siding Vent Kit
DVC-35IP
35,000
72 1/2"
14 1/8"
10 3/8"
1/2" Pipe
275
32189-2-0414