WARNING: If the information in these instructions
are not followed exactly, a fire or explosion may
result causing property damage, personal injury
or loss of life.
— Do not store or use gasoline or other flammable
vapors and liquids in the vicinity of this or any
other appliance.
— WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electrical switch; do not use
any phone in your building.
Immediately call your gas supplier from a
neighbor's phone. Follow the gas supplier's
instructions.
If you cannot reach your gas supplier, call the
fire department.
— Installation and service must be performed by a
qualified installer, service agency or the gas sup-
plier.
INSTALLATION INSTRUCTIONS
OWNER'S MANUAL
Installer:
Consumer:
This appliance may be installed in an aftermarket,
permanently located manufactured home (USA only)
or mobile home, where not prohibited by state or local
codes.
This appliance is only for use with the type of gas
indicated on the rating plate. This appliance is not
convertible for use with other gases, unless a certified
kit is used.
WARNING: If not installed, operated and maintained
in accordance with the manufacturer's instructions,
this product could expose you to substances in fuel
or from fuel combustion which can cause death or
serious illness.
AND
FAN TYPE
DIRECT VENT
WALL FURNACE
MODEL
DVC-35-2SPP
DVC-35-2IP
Leave this manual with the appliance.
Retain this manual for future reference.
Page 1

Publicité

Chapitres

Table des Matières
loading

Sommaire des Matières pour Empire DVC-35-2SPP

  • Page 1 INSTALLATION INSTRUCTIONS OWNER’S MANUAL FAN TYPE DIRECT VENT WALL FURNACE MODEL DVC-35-2SPP DVC-35-2IP Installer: Leave this manual with the appliance. WARNING: If the information in these instructions Consumer: Retain this manual for future reference. are not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life.
  • Page 2: Table Des Matières

    TABLE OF CONTENTS SECTION PAGE Important Safety Information ..................3 Safety Information for Users of LP Gas ..............4 Requirements for Massachusetts ................5 Introduction ......................6 Specifications ......................6 Gas Supply ......................7-8 Clearances .......................8 Installation Instructions ..................9-11 DVC-35SPP Standing Pilot Lighting Instructions ...........12 DVC-35IP Intermittent Pilot Lighting Instructions ...........13 Pilot Flame Characteristics ..................14 Main Burner Flame Characteristics ................15 Wiring ........................15-16...
  • Page 3: Important Safety Information

    IMPORTANT SAFETY INFORMATION THIS IS A HEATING APPLIANCE DO NOT OPERATE THIS APPLIANCE WITHOUT FRONT PANEL INSTALLED. • Due to high temperatures, the appliance should be • DO NOT put anything around the furnace that will located out of traffic and away from furniture and obstruct the flow of combustion and ventilation air.
  • Page 4: Safety Information For Users Of Lp Gas

    SAFETY INFORMATION FOR USERS OF LP-GAS Propane (LP-Gas) is a flammable gas which can cause fires SOME POINTS TO REMEMBER and explosions. In its natural state, propane is odorless and • Learn to recognize the odor of LP-gas. Your local LP-Gas colorless.
  • Page 5: Requirements For Massachusetts

    REQUIREMENTS FOR MASSACHUSETTS For all side wall horizontally vented gas fueled equipment installed SIGNAGE. A metal or plastic identification plate shall be per- in every dwelling, building or structure used in whole or in part for manently mounted to the exterior of the building at a minimum residential purposes, including those owned or operated by the height of eight (8) feet above grade directly in line with the Commonwealth and where the side wall exhaust vent termination...
  • Page 6: Introduction

    INTRODUCTION Introduction so that all burners and burner ignition devices are located not less Always consult your local Building Department regarding regula- than 18” above the floor. tions, codes or ordinances which apply to the installation of a di- Such equipment shall be located, or protected, so it is not subject rect vent wall furnace.
  • Page 7: Gas Supply

    GAS SUPPLY Locating Gas Supply Installing a New Main Gas Cock The gas line can enter the unit either through the floor or outside Each appliance should have its own manual gas cock. wall. The gas line opening should be made at this time. Location A manual main gas cock should be located in the vicinity of the of the opening will be determined by the position of floor joists and unit.
  • Page 8: Clearances

    Checking Manifold Pressure Both Propane and Natural gas valves have a built-in pressure regulator in the gas valve. Natural gas models will have a manifold TOP VIEW OF VALVE pressure of approximately 4.0” w.c. (.996kPa) at the valve outlet PRESSURE REGULATOR with the inlet pressure to the valve from a minimum of 5.0”...
  • Page 9: Installation Instructions

    INSTALLATION INSTRUCTIONS Locating Wall Opening The furnace is to be located on an outside wall. Locate wall studs so that wall opening will be located between wall studs. The fur- naces is 14 1/8” (358mm) in width and can be recessed between standard 16”...
  • Page 10 Locating Electric Supply 3. Mark or wrap tape completely around the tubes at the marked A 7/8” (22mm) diameter knockout is provided at the bottom of the points to help in making a true cut. Do not crimp or enlarge left and right side panels.
  • Page 11 INSTALLATION INSTRUCTIONS (continued) Vinyl siding kit, DV-822, is available from Empire Comfort Sys- Reassembly and Resealing Vent-Air Intake System tems, Inc. The depth is 3” (76mm), which enables the vent cap to When vent-air intake system is removed for servicing the furnace, be extended away from siding or projections.
  • Page 12: Dvc-35Spp Standing Pilot Lighting Instructions

    DVC-35 SPP STANDING PILOT LIGHTING INSTRUCTIONS FOR YOUR SAFETY READ BEFORE LIGHTING WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. A. This appliance has a pilot which must be lighted by hand. C.
  • Page 13: Dvc-35Ip Intermittent Pilot Lighting Instructions

    DVC-35IP INTERMITTENT PILOT LIGHTING INSTRUCTIONS FOR YOUR SAFETY READ BEFORE LIGHTING WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. A. This appliance is equipped with an ignition device which C.
  • Page 14: Pilot Flame Characteristics

    PILOT FLAME CHARACTERISTICS The correct pilot flame (Figure 11) will be blue, extending past the THERMOCOUPLE thermocouple. The flame will surround the thermocouple just be- low the tip. Natural gas pilots require adjusting when the inlet gas pressure is above 5” w.c. (1.245kPa). Remove the pilot cover screw on the BURNER control valve (Figure 3), and turn the adjustment screw clockwise to reduce flame.
  • Page 15: Main Burner Flame Characteristics

    MAIN BURNER FLAME CHARACTERISTICS The correct flame will be a short, blue inner flame with a much larger, light blue, outer flame. The burner does not have a primary air adjustment. The flame will be correct if the factory-set pressure and orifice opening are used.
  • Page 16 PRESSURE REGULATOR ADJUSTMENT-UNDER CAP SCREW OUTLET PRESSURE TAP INLET PRESSURE TAP PILOT ADJUSTMENT- UNDER CAP SCREW GAS FLOW PILOT OUTLET IGNITOR-PILOT ASSY. WIRING TO 24 V. THERMOSAT TO 24 V. COMMON ON TRANSFORMER TO 24 V. “HOT” ON TRANSFORMER IP-MODEL GAS VALVE AND WIRING L1 “HOT”...
  • Page 17: Service And Maintenance Suggestions

    4. Type of gas being used and that shown on the rating label. 2. Check burner door and pilot hole cover for tight seal. The Service Department at Empire Comfort Systems, Inc. may be 3. Check input by manifold pressure gauge or gas meter.
  • Page 18: Dvc-35Ip Intermittent Pilot Sequence Of Operation

    DVC-35IP INTERMITTENT PILOT SEQUENCE OF OPERATION Apply 24 VAC START To Appliance Thermostat Calls for Heat 5 Minute Retry Delay Pilot Valve Ignition OFF Flame Signal Wait for Flame Signal to Detected Disappear System Check Internal Check Trial for Pilot Valve Opens Ignition Ignitor Powered Pilot Light and Flame is...
  • Page 19: Dvc-35Ip Intermittent Pilot System Troubleshooting Sequence

    DVC-35IP INTERMITTENT PILOT SYSTEM TROUBLESHOOTING SEQUENCE START IP SYSTEM TROUBLESHOOTING SEQUENCE Turn OFF Gas Supply Disconnect System Control SmartValve System Troubleshooting Sequence End View INSET A 24 Volt Harness of Control Note: Before Troubleshooting, Become Familiar Thermostat Harness Set Thermostat to Call for with the Sequence of Operation Connector Heat...
  • Page 20: Parts List

    PARTS LIST PLEASE NOTE: When ordering parts, it is very important that part number and description of part coincide. INDEX INDEX PART NO DESCRIPTION PART NO DESCRIPTION DV1213 TOP PLATE OBSERVATION HOLE COVER WITH DV781 MICA R3165 DOOR CLIP (2 REQUIRED) M155 GASKET - OBS HOLE DV1204...
  • Page 21: Parts View

    PARTS VIEW 32189-2-0414 Page 21...
  • Page 22: Master Parts Distributor List

    MASTER PARTS DISTRIBUTOR LIST To Order Parts Under Warranty, please contact your local Empire dealer. See the dealer locator at www.empirecomfort. com. To provide warranty service, your dealer will need your name and address, purchase date and serial number, and the nature of the problem with the unit.
  • Page 23: Warranty

    WARRANTY Empire Comfort Systems Inc. warranties this space heating product to be free from defects at the time of purchase and for the periods specified below. Space heating products must be installed by a qualified technician and must be maintained and operated safely, in accordance with the instructions in the owner’s manual.
  • Page 24 Empire Comfort Systems Inc. EMPIRE EMPIRE 918 Freeburg Ave. Belleville, IL 62220 If you have a general question about our products, please e-mail us at info@empirecomfort.com. If you have a service or repair question, please contact your dealer. Comfort Systems www.empirecomfort.com...
  • Page 25: Radiateur Mural Àcirculation Forcée Avec Un Évent Direct

    INSTRUCTIONS POUR L’INSTALLATION ET MANUEL DU PROPRIÉTAIRE RADIATEUR MURAL À CIRCULATION FORCÉE AVEC UN ÉVENT DIRECT MODÈLES DVC-35-1SPP DVC-35-1IP AVERTISSEMENT: Assurez vous de bien suivre les instructions données dans cette notice pour réduire au minimum le risque d’incendie ou d’explosion ou pour éviter tout dommage matériel, Installateur: Laissez cette notice avec l’appareil.
  • Page 26 TABLE DES MATIÈRES SECTION PAGE Importante Information de Sécurité ..................3 Information de Sécurité pour les Utilisateurs de Propane ............4 Introduction ..........................5 Spécifications..........................5 Alimentation en Gaz .......................6 Espaces Libres ........................7 Instructions pour L'Installations ..................8-10 Instructions d'Allumage de la Veilleuse Fixe pour le Modèle DVC-35SPP .....11 Instructions d'Allumage de la Veilleuse Intermittente pour le Modèle DVC-35IP ....12 Aspect Convenable de la Flamme de la Veilleuse ..............13 Aspect Convenable de la Flamme du Brûleur Principal ............14...
  • Page 27: Importante Information De Sécurité

    IMPORTANTE INFORMATION DE SÉCURITÉ CECI EST UN APPAREIL DE CHAUFFAGE NE PAS FAIRE FONCTIONNER CET APPAREIL SANS QUE LA PAROI FRONTALE SOIT INSTALLÉE. • A cause des hautes températures, cet appareil doit être situé • Ne rien mettre autour du radiateur qui pourrait obstruer le dans un endroit non achalandé...
  • Page 28: Information De Sécurité Pour Les Utilisateurs De Propane

    INFORMATION DE SÉCURITÉ POUR LES UTILISATEURS DE PROPANE Le propane est un gaz inflammable qui peut causer des feux et des ex- point par point avec les membres de votre famille. Un jour, lorsqu’il n’y plosions. Dans son état naturel, le propane est inodore et sans couleur. aura pas une minute à...
  • Page 29: Introduction

    INTRODUCTION Introduction Installation dans les Garages Residentiels Toujours consulter le département de construction de votre région en ce Tous les équipements dans les garages résidentiels employant du gaz, qui regarde les règlements, les codes ou les ordonnances qui s’appliquent doivent être installés de façon à ce que les brûleurs et les appareils pour à...
  • Page 30: La Provision De Gaz

    LA PROVISION DE GAZ Emplacement de l'Alimentation de Gaz La ligne de gaz peut entrer dans l’appareil soit en venant du plancher ou Un robinet manuel principal doit être situé près de l’appareil. S’il n’y en du mur extérieur. L’ouverture pour la ligne de gaz doit être faite à ce mo- a pas ou si la grosseur ou l’emplacement est inadéquat, contacter votre ment.
  • Page 31: Espaces Libres

    Vérifier les Pressions de Gaz VALVE VUE DE DESSUS Un régulateur de pression est incorporé dans la valve de gaz propane et RÉGULATEUR DE PRESSION ÉVENT celle de gaz naturel. Les modèles pour le gaz naturel auront des pressions CONNECTEUR TH/TR PRISE POUR SORTIE DE de gaz approximativement de 4"...
  • Page 32: Instructions Pour L'installations

    INSTRUCTIONS POUR L'INSTALLATION Emmplacement de l’Ouverture dans le Mur volets dans la position désirée pour la sortie d’air et marquer les trous de montage en utilisant le registre comme guide. Le radiateur doit être situé sur un mur extérieur. Trouver les montants du mur, ainsi l’ouverture dans le mur sera entre les montants du mur.
  • Page 33 le tuyau d’arrivée d’air de 6" (152mm) de diamètre aussi loin que Emplacement de l’Alimentation Electrique possible sur le collet de l’assemblage de la descente d’air. Marquer le Sur le bas des panneaux des côtés gauche et droit, il y a une entrée défon- tuyau d’arrivée d’air de 6"...
  • Page 34 DV-1190, l’ensemble d’extension du tuyau d’évacuation. L’ensemble d’évent pour le revêtement en vinyle, DV-822, est disponible chez Empire Comfort Systems. L’épaisseur est de 3" (76mm) ce qui permet le prolongement du capuchon d’évent loin du revêtement ou des saillies. L’épaisseur du mur, plus l’épaisseur additionnelle de 3" (76mm) de l’extension du capuchon d’évent pour revêtement ne doit pas excéder...
  • Page 35: Instructions D'allumage De La Veilleuse Fixe Pour Le Modèle Dvc-35Spp

    INSTRUCTIONS D'ALLUMAGE DE LA VEILLEUSE FIXE POUR LE MODÈLE DVC-35SPP POUR VOTRE SÉCURITÉ LIRE AVANT D’ALLUMER AVERTISSEMENT: Si vous ne suivez pas exactement ces instructions, un feu ou une explosion peut se produire causant des dommages à la propriété, des blessures corporelles ou la mort. A.
  • Page 36: Instructions D'allumage De La Veilleuse Intermittente Pour Le Modèle Dvc-35Ip

    INSTRUCTIONS D'ALLUMAGE DE LA VEILLEUSE INTERMITTENTE POUR LE MODÈLE DVC-35IP POUR VOTRE SÉCURITÉ LIRE AVANT D’ALLUMER AVERTISSEMENT: Si vous ne suivez pas exactement ces instructions, un feu ou une explosion peut se produire causant des dommages à la propriété, des blessures corporelles ou la mort. A.
  • Page 37: Aspect Convenable De La Flamme De La Veilleuse

    ASPECT CONVENABLE DE LA FLAMME DE LA VEILLEUSE La flamme de la veilleuse (Figure 11) sera bleue et s’allongera plus loin THERMOCOUPLE que le thermocouple. La flamme entourera le thermocouple juste en- dessous de la pointe. Les veilleuses au gaz naturel exigent un ajustement lorsque la pression d’entrée de gaz est supérieure à...
  • Page 38: Aspect Convenable De La Flamme Du Brûleur Principal

    ASPECT CONVENABLE DE LA FLAMME DU BRÛLEUR PRINCIPAL La flamme convenable aura une petite flamme bleue intérieure avec une flamme extérieure bleue pâle beaucoup plus grande. Il n’y a pas d’ajustement d’air primaire pour le brûleur. La flamme se corrigera si la pression pré- ajustée à...
  • Page 39 AJUSTEMENT DU RÉGULATEUR DE PRESSION SOUS COUVERT VISSÉ PRISE DE LA PRESSION DE SORTIE AJUSTEMENT DE LA PRISE DE LA PRES- VEILLEUSE - SOUS SION D'ENTRÉE COUVERT VISSÉ ECOULEMENT DU GAZ VENTILATEUR SORTIE DE LA VEILLEUSE ALLUMEUR VEILLEUSE ASSY. INSTALLATION ÉLECTRIQUE AU THERMOSTAT DE 24V.
  • Page 40: Suggestions Pour Le Service Et L'entretien

    Pour vous assister à l’entretien du radiateur, vous pouvez contacter le 3. Vérifier l’entrée avec un manomètre ou un gazomètre. département de service à Empire Comfort Systems, Inc. Valve principale de gaz ne s’ouvre pas lorsque le thermostat est tourné à...
  • Page 41: Séquence De Fonctionnement De La Veilleuse Intermittente Pour Le Modèle Dvc-35Ip

    SÉQUENCE DE FONCTIONNEMENT DE LA VEILLEUSE INTERMITTENTE POUR LE MODÈLE DVC-35IP Appliquer 24 VAC à DÉPART l'appareil Thermostat Effectue un Appel de Chaleur Délai de 5 minutes, Essai de Nouveau - Allumage de la Soupape Signal de la Flamme est de la Veilleuse OFF Détecté...
  • Page 42: Guide De Détection Des Défectuosités Du Système De La Veilleuse Intermittente Pour Le Modèle Dvc-35Ip

    GUIDE DE DÉTECTION DES DÉFECTUOSITÉS DU SYSTÈME DE LA VEILLEUSE INTER- MITTENTE POUR LE MODÈLE DVC-35IP Départ - Fermer l'Alimentation de Gaz GRAPHIQUE A - Débrancher le Harnais du Vue de l'extrémité Système de Contrôle Guide de détection des défectuosités pour le système Thermostat des connecteurs de 24 Volt...
  • Page 43: Liste Des Distributeurs De Pièces Principaux

    LISTE DES DISTRIBUTEURS DE PIÈCES PRINCIPAUX Pour commander des pièces sous garantie, adressez-vous au revendeur Empire local. Veuillez voir le concessionnaire au www.empirecomfort.com. Pour assurer un service sous garantie, le revendeur doit connaître votre nom, votre adresse, la date d’achat et le numéro de série du produit, ainsi qui la nature du problème.
  • Page 44: Listes Des Pièces

    LISTE DES PIÈCES S’IL VOUS PLAÎT NOTER: Lorsque vous commandez les pièces, il est très important que le numéro de la pièce et la description coïncident. Numéro Numéro Description Numéro Numéro Description d’index de la pièce d’index de la pièce DV-1265 Corps du compartiment du brûleur DV-1213...
  • Page 45: Vue Des Pièces

    VUE DES PIÈCES VEILLEUSE ET SUPPORT POUR LES MODÉLES SPP 32189-2-0414 Page 21...
  • Page 46: Garantie

    En cas de défaillance d’une télécommande, d’un thermostat, d’un accessoire ou autre pièce en raison de défauts de main- d’œuvre dans un délai d’un an à compter de la date d’achat, Empire s’engage à la réparer ou à la remplacer, au choix d’Empire.
  • Page 47: Maintenance Historique De L'appareil

    MAINTENANCE HISTORIQUE DE L’APPAREIL Date Nom du distributeur Nom du technicien de service Entretien effectué/notes 32189-2-0414 Page 23...
  • Page 48 Empire Comfort Systems Inc. EMPIRE EMPIRE 918 Freeburg Ave. Belleville, IL 62220 Pour toute question générale concernant nos produits, veuillez nous envoyer un courriel à info@empirecomfort.com. Pour toute question d’entretien ou de réparation, veuillez contacter votre revendeur. Comfort Systems www.empirecomfort.com...

Ce manuel est également adapté pour: