4.2
LED
ON
OFF
MODE
S
P
ALARM
NC
NO
5. Operation
5.1
•
•
•
•
•
•
•
V. 03 – 08/06/2020
Jumper Settings
Enables the LED
ON = alarm activated.
FLASH = power-up.
Disables the LED. Does not affect detection.
Standard alternate polarity signal processing. For
operation within a stable environment.
Double alternate polarity signal processing within 10
seconds. For a harsh environment.
The alarm relay output contact is NC. The output relay
is normally energized.
The alarm relay output contact is NO. The output relay
is normally de-energized.
Mounting Location
The detector can be surface or corner mounted, or mounted
with the supplies swivel bracket. Always mount the unit on a
sturdy surface.
The detector should be mounted indoors, in areas that do
not have openings constantly exposed to the outside
environment.
Select the mounting location so that the expected
movement of an intruder will cross the detection beam.
Do not locate the detector where hot or cold moving air will
blow directly onto the unit.
Avoid aiming the detector towards heating or air
conditioning vents or ducts, exterior metal walls, exterior
windows or curtains covering windows, refrigerator or
freezer grills or other surfaces that may change temperature
rapidly.
Avoid putting large objects in front of the detector, which
will cause significant changes in the area or volume
protected.
Select the mounting location so that the beam patterns are
at a 45° angle to the intruder's expected path. Installation
height should be 2 ~ 3m.
HAA52N
5
©Velleman nv