Troubleshooting
Error messages
Memory full
BARman 's memory cannot accept
further information.
Battery empty
BARman 's battery is empty; this
status freeze the keypad.
Battery defect
BARman
was a long time out of
its base station.
or
BARman 's battery is worn out.
Function error
Function called is not present.
Format error
The table has an incorrect format.
Program error
No program present.
Program overlaps the firmware
Table error
Bad number of tables or no table
declared in the program.
Memory error
Program or table out of memory.
3
Chapter
Remedy
Transfer BARman 's data into the
computer before using again.
Your BARman
can be unfreezed by
placing it on its base station for at
least 4 minutes. Total recharge will
take 5 1/2 h.
Recharge it.
Ask
your authorised
dealer
to
replace it immediately.
Check firmware and compiler
version.
Run AXVERIFY.
Download a program to BARman
.
Compile the program at a higher
address
Download all the tables or verify the
program.
Scale down the program or the
tables.
19