STEP 6
Insert the 12 volt DC power supply wires into
the open hole in the side of the metal switch
bracket on the MAXXFAN MINI. Allowing 4 to
6 inches of wire inside the bracket, secure the
wires to the bracket with the supplied strain
relief bushing.
Using the supplied wire nuts,
connect the Positive (+)12VDC supply wire to the
MAXXFAN MINI wire(s) marked "Pos. 12 VDC"
and the Negative (-)12VDC supply wire to the
MAXXFAN MINI wire marked "Neg. 12 VDC".
STRAIN RELIEF BUSHING
STEP 7
Route supply wires to notch in the back of the
MAXXFAN MINI interior plate, place sleeve over
interior plate with supply wires routed through
hole formed between interior plate and sleeve.
STEP 8
Raise interior plate/sleeve to ceiling and ensure
that sleeve meshes with MAXXFAN MINI roof
top flange. Refer to screw lengths in the table
of STEP 2 and use the proper length screws
depending on your roof thickness to secure the
interior plate to the roof top flange, taking care
not to overtighten the screws to avoid cracking or
deforming the interior plate.
STEP 9
Reconnect main vehicle power to the MAXXFAN
MINI / MINI PLUS.
INSTALLATION OF YOUR MAXXFAN
OR MAXXFAN
WIRE NUTS
MAXXFAN
Operation simply entails turning the ON/OFF
switch to activate the exhaust fan or (optionally)
the LED lighting.
interior plate to allow maximum airflow. Close
baffle to impede infiltration of air when exhaust
fan is not in use.
FUSE HOLDER
12 VDC SUPPLY WIRES
Replacing the fuse of your MAXXFAN MINI /
MAXXFAN MINI PLUS:
a. Remove the 4 screws that hold the interior
b. Locate the fuse holder and remove the fuse
c. Risk of fire. Replace the fuse with 5Amp,
SLEEVE
d. Place one end of the fuse in the male side of
e. Screw the two halves of the fuse holder
f.
g. Secure the interior plate to the roof top
Cleaning of your MINI may be achieved with
mild soap and water only. Before removing the
12 VDC SUPPLY WIRES
screen for cleaning, ensure the fan is turned to
the OFF position. CAUTION: Do not operate
INTERIOR PLATE
the fan with the screen removed.
Should you have questions, please contact
AIRXCEL
SOLUTIONS Customer Service at 316.832.4357.
3
THIS COMPLETES THE
MINI PLUS.
®
OPERATION OF YOUR
MINI / MAXXFAN MINI PLUS
®
Open the air baffle in the
USER SERVICING INSTRUCTIONS
plate in place and lower the interior plate.
carefully by turning the fuse holder counter
clockwise
125V fuse.
the fuse holder.
together by turning in the clockwise direction
until snug.
Raise interior plate/sleeve to ceiling and
ensure that sleeve meshes with MINI roof top
flange.
flange using the 4 screws, taking care not to
overtighten the screws to avoid cracking or
deforming the interior plate.
/
MAXXAIR
INTERIOR PLATE
SCREW (4)
MINI
®
VENTILATION