Filter-types
Prefilter:
Depending on the design models (see technical data) the exhaust – and filter system is
equipped with various exchangeable pre-filters (for example: Al-Filter (G3), filter mat (F5),
Z-Line-Filter (F6-F7), bag-filter(F6-F7). With the periodical replacement of the pre-filters the
life time of the downstream main-filter will be significant increased.
Main-filter:
Due to the main-filter it is warranted that more as 99,95% of the exhausted fume- and dust
particles will stay in the filter. This is valid, if the filter is completely or partly saturated. With
the increasing saturation the suction power becomes lower.
Activated carbon
The saturation time of the activated carbon filter depends on the operating conditions and
can not be predetermined. The activated carbon filter has to be replaced if the unpleasant
odor recurs. That means that the rate of saturation is reached for the activated carbon.
GL400-rev. 2.00
:
(Only for Units of the LN / GL and OEN Series)
-22-
Technical changes reserved / Sous réserve de modifications techniques
Cambios técnicos reservados / Con riserva di modifiche tecniche