5. When installing the High Flow™ manual air relief valve
position the filter to safely direct water drainage. Rotate the
High Flow™ manual air relief valve to safely direct purged air
or water. Water discharged from an improperly positioned
filter or valve can create an electrical hazard as well as damage
to property.
Risk of electrical shock or electrocution. Position the filter and High Flow™ manual air relief valve to safely direct water
drainage and purged air or water. Water discharged from an improperly positioned filter or valve can create an electrical hazard
that can cause severe injury as well as damage property.
6. Your filter requires one of the following Pentair Pool Products accessories which must be purchased separately.
a.
Push-pull valve.
b.
Multiport valve.
c.
Bulkhead union set.
7. Make all plumbing connections in accordance with local plumbing and building codes. Filter plumbing connections are
provided with an O-ring seal. Use only a silicone base lubricant on the O-rings. Do not use pipe joint compound, glue or
solvent on the bulkhead connections to avoid damage to the O-rings.
For Multiport control valves with threaded ports use only Teflon tape, 100% pure Teflon paste (non-petroleum base), Permatex #2 sealant
on all threaded pipe connections, except fittings with O-rings. Use of other pipe joint compounds can damage components of this system
and cause leaks. For control valves with slip ports, use only ABS to PVC solvent welding adhesive.
8. The maximum working pressure of this filter is 50 psi, see Table 2. Never subject this filter to pressure in excess of this amount
- even when conducting hydrostatic pressure tests. Pressures above maximum working pressure can cause the lid to be blown
off, which can result in severe injury, death or property damage.
When performing hydrostatic pressure tests or when testing for external leaks of the completed filtration and plumbing
system, insure that the Maximum Pressure that the filtration system will be subjected to DOES NOT EXCEED THE
MAXIMUM WORKING PRESSURE OF ANY OF THE COMPONENTS CONTAINED WITHIN THE SYSTEM. In most
cases, the maximum pressure will be stated on each component of the system.
If doubt exists as to the pressure to which the system will be subjected, install an ASME approved automatic Pressure Relief
or Pressure Regulator in the circulation system for the lowest working pressure of any of the components in the system.
SECTION II.
FILTER OPERATION AND CLEANING.
THIS FILTER OPERATES UNDER HIGH PRESSURE. WHEN ANY PART OF THE CIRCULATING SYSTEM (E.G., CLAMP,
PUMP, FILTER, VALVES, ETC.) IS SERVICED, AIR CAN ENTER THE SYSTEM AND BECOME PRESSURIZED.
PRESSURIZED AIR CAN CAUSE THE LID OR CONTROL VALVE TO BLOW OFF WHICH CAN RESULT IN SEVERE INJURY,
DEATH, OR PROPERTY DAMAGE. TO AVOID THIS POTENTIAL HAZARD, FOLLOW THESE INSTRUCTIONS.
1.
BEFORE REPOSITIONING VALVES AND BEFORE BEGINNING THE ASSEMBLY, DISASSEMBLY, OR ADJUSTMENT
OF THE CLAMP OR ANY OTHER SERVICE OF THE CIRCULATING SYSTEM: (A) TURN THE PUMP OFF AND SHUT
OFF ANY AUTOMATIC CONTROLS TO ENSURE THE SYSTEM IS NOT INADVERTENTLY STARTED DURING THE
SERVICING; (B) OPEN HIGH FLOW™ MANUAL AIR RELIEF VALVE; (C) WAIT UNTIL ALL PRESSURE IS RELIEVED,
PRESSURE GAUGE MUST READ ZERO (0).
2.
WHENEVER INSTALLING THE FILTER CLAMP, FOLLOW THE FILTER LID AND CLAMP INSTALLATION
INSTRUCTIONS EXACTLY.
3.
ONCE SERVICE ON THE CIRCULATING SYSTEM IS COMPLETE, FOLLOW SYSTEM RESTART INSTRUCTIONS
EXACTLY.
4.
MAINTAIN CIRCULATION SYSTEM PROPERLY. REPLACE WORN OR DAMAGED PARTS IMMEDIATELY (E.G.,
CLAMP, PRESSURE GAUGE, RELIEF VALVE, O-RINGS, ETC.).
5.
BE SURE THAT THE FILTER IS PROPERLY MOUNTED AND POSITIONED ACCORDING TO INSTRUCTIONS
PROVIDED.
P/N • Núm/Pte. • Réf. P/N 99226000
Model
58920100
58920200
58920300
WARNING
CAUTION
WARNING
2
Table 1.
Size
Vert. Clear. Req.
3.5 sq. ft.
49 in.
4.6 sq. ft.
51 in.
6.5 sq. ft.
57 in.
Rev. H • Rev. H • Rév. H
5-15-01