18.
TROUBLESHOOTING
A
LEAKAGE WITH MULTIFASTER CONNECTED
A1
Locate the leaking line by examining the draining holes on the sides of
the fixed part.
A2
Disconnect the
Replace the damaged seal N of the leaking male coupling.
A3
A4
Connect the
line.
In case leakage continues, replace the female coupling L too and
A5
proceed as described within steps A3 and A4.
A6
If leakage continues again, verify that the lever are not deformed. This
could cause a misalignement of the
consequence, the seals breaking during connection.
B
LEAKAGE AFTER CONNECTION UNDER PRESSURE
Proceed as described within steps A1 - A2 - A3 - A4.
B1
In case leakage continues, replace both the female coupling L and the
B2
male coupling M of the specific line.
B3
If leakage continues again, proceed as described within step A6.
C
LEAKAGE FROM DISCONNECTED MOBILE PART
C1
Locate the leaking line.
C2
Proceed as described within steps A3 - A4.
In case leakage continues, replace the male coupling M of the specific
C3
line.
If leakage continues again, replace the female coupling L and the seal
C4
N of the male coupling.
C5
If leakage goes on, proceed as described within step A6.
D
LEAKAGE FROM DISCONNECTED FIXED PART
Locate the leaking line.
D1
Replace the female coupling L of the specific line.
D2
MULTIFASTER
MULTIFASTER
36
.
and increase the pressure in the specific
MULTIFASTER
and, as a