OVERVIEW
• The individual push-buttons on the
APCECOD make changing settings EASY.
• Press a button, the display shows the
current setting.
• To change the settings, use the UP and
DOWN buttons.
• Then press ENTER to accept the new setting.
HOW TO CUSTOMIZE SETTINGS
UP - Press button (up arrow) to increase setting
DOWN - Press button (down arrow) to decrease setting
ENTER/RESET – The ENTER/RESET button is used to accept new settings and to RESET some errors.
CO
PPM setting - Press CO
2
the Up or Down buttons. Press ENTER to accept new setting.
CO
Deadband setting - Press CO
2
change settings press the Up or Down buttons. Press ENTER to accept new setting.
CO
Function setting - Press CO
2
hours). To change settings press the Up or Down buttons. Press ENTER to accept new setting.
CO
Mode setting - Press CO
2
change settings press the Up or Down buttons. Press ENTER to accept new setting.
Min/Max Recall - Press to "recall" or display the minimum and maximum CO
time the button is pressed, the next setting will be displayed.
NOTE: To reset the Min/Max values: when the recorded value is displayed, press the ENTER/RESET
button. Pressing repeatedly will RESET each value sequentially.
PHOTOCELL SENSITIVITY
The sensitivity of the photocell may be adjusted.
• Press the Down button and hold for 3 seconds. The current photocell setting will be displayed.
• Press Up to increase the number displayed and the sensitivity. (Requires less light to activate
photocell)
• Press Down to decrease the number and the sensitivity. (Requires more light to activate photocell)
FUZZY LOGIC CO
"Fuzzy Logic" CO
mode allows the user to more precisely control the CO
2
area. Fuzzy Logic works by monitoring the rising or falling CO
activating ON / OFF the CO
Fuzzy Logic mode can be activated or deactivated by pressing the Fuzzy Logic button. Press Up or
Down to select generator mode (gEnErAt) if using CO
compressed CO
. Press ENTER to accept new setting.
2
4
www.Hydrofarm.com
INSTRUCTIONS
PPM, The current PPM setting will be displayed. To change settings press
2
DEAD BAND. The current CO
2
Function, The photocell setting will be displayed (Day-Night or 24
2
Mode, The current CO
2
MODE
2
solenoid valve. This function can ONLY be used with compressed CO
2
deadband setting is displayed. To
2
mode will be displayed (Increase or Decrease). To
2
level and reacting to it by quickly
2
generator or Fuzzy logic mode (LogIcon) if using
2
recorded values. Each
2
levels inside the growing
2
.
2