Remote Control BIP
Characteristics
BIP features 8 channels pre-associated to the relay outputs of INT WS
It is possible to obtain that pressing one of the buttons the concerned relay is activated in "status" or "pulse" mode.
Association of the pushbuttons – relay outputs
C
h
a
n
2
1
2
3
5
4
3
4
5
6
7
8
Acquisition of remote controls
It is possible to acquire up to 16 (sixteen) remote controls for any group (max.4) which must be codified according to
the chart given within the BIP.
It is not possible to acquire more remote controls with the same coding in the same group.
In order to acquire a remote control, transmit in proximity of the receiver, taking into consideration that pressing on a
certain pushbutton will cause the corresponding relay output of the receiver to be associated to that remote control.
(See chart)
It is possible to acquire more pushbuttons for any remote control.
Example: if the pushbuttons 1 and 5+2 are pressed, the remote control
will activate the relay outputs 1 and 6.
1. Set dip 4 in ON; it is possible to select four groups of remote
controls (any group contains up to 16 remote controls) through
dip 5 and 6 according to the chart; only afterwards, set dip 1
to ON.
2. Press the pushbuttons of the remote control that you wish to acquire
3. INT WS emits a sound, shows the number of remote control on the display (two figures in sequence) and the
number of the pushbutton on the Led bar
4. The output corresponding to the pushbutton is linked to the output of the associated relay (Es. Pushbutton n.
3 = output n. 3 of the relays); furthermore, the output reserved to the remote control looses the standard
function of radio detectors "status"
5. Put again, for first, dip 1 to OFF, then the others
STATUS or PULSE Function
When the pushbuttons are acquired, the relay output is associated in "status" activation mode
It is possible to obtain that the output associated to the remote controls is set in "pulse" mode
1.
Set dip 7 in ON and dip 4 in ON, only afterwards set dip 1 in ON
2.
Press the pushbutton of any remote control
3.
The relay output corresponding to the pushbutton becomes "pulse" with duration of 3 seconds
4.
Put again, for first, dip 1 in OFF, then the others
Note: the codification of the remote controls must be set as one, two, three until max sixteen for group
Functioning
When an output of the remote control is activated, the display will show the letter "o" and the Led bar will show the
active outputs, any possible indication of alarm on the zones with usual letters "a", "b", "c", "d" will then follow.
Total restore of INT WS board
The restore of the factory settings and the cancellation of all remote controls and of the "status-pulse" settings of the
outputs is obtained following the procedure of total cancellation of the detectors, described in the manual.
B
t u
o t
n
s
A
n
e
s l
o t
p
e r
s
s
1
•
1
•
•
2
•
•
3
•
•
4
•
•
5
+
1
•
•
5
+
2
•
•
5
+
3
•
•
5
+
4
•
s
s
o
c
a i
e t
d
Pushbuttons Functioning
e r
a l
y
The buttons from 1 to 4 and from 5+1 to 5+4
1
directly activate the relays to which they are
2
associated.
3
Note: the relays, whether associated to the remote
4
control, loose their original function of detectors
5
"status
6
7
8
s
e
w
i h
- 29 -
e l
t c
o i
n
f o
D
P I
5
e t
b
t u
o t
n
1
•
o
f f
•
2
•
o
f f
•
3
•
o
n
•
4
•
o
n
•
E
N
G
D
P I
6
o
f f
o
n
o
f f
o
n