Connection of Sat W (s) to control unit

In order to connect SAT W (s), refer to scheme and following indications, connecting terminals
to series RS485 output of control unit and to corresponding terminals on circuit.
More extension boards can be connected in parallel on the same serial RS485 door.
Connected extension boards can be of different models (SAT03, SAT04 and Sat W (s))
as long as they have different setting out (Please refer to setting out of detectors):
Shielded, 4 wires (0,5 mm section) cables are suggested
Total length of connection cable can be 600 meters and must be split among all
connected devices to serial RS485 door (extension boards, keyboards etc.)
E
N
G

Connection of Int W (s) to control unit

For connection of Int W (s) extension board refer to scheme here below
Use multi-wires shielded cables: 0,5 mm Ø for supplying and 0,22 mm Ø for outputs and
inputs.
For connection of 8 outputs and of tamper, a 2x0,50+10x0,22 m cable is required
For connection of 3 Open Collector outputs, of X (control unit status) and T (tamper
output), other 5x0,22 mm wires are required.