Connection of Sat W (s) to control unit
In order to connect SAT W (s), refer to scheme and following indications, connecting terminals
to series RS485 output of control unit and to corresponding terminals on circuit.
•
More extension boards can be connected in parallel on the same serial RS485 door.
•
Connected extension boards can be of different models (SAT03, SAT04 and Sat W (s))
as long as they have different setting out (Please refer to setting out of detectors):
•
Shielded, 4 wires (0,5 mm section) cables are suggested
•
Total length of connection cable can be 600 meters and must be split among all
connected devices to serial RS485 door (extension boards, keyboards etc.)
E
N
G
Connection of Int W (s) to control unit
For connection of Int W (s) extension board refer to scheme here below
•
Use multi-wires shielded cables: 0,5 mm Ø for supplying and 0,22 mm Ø for outputs and
inputs.
•
For connection of 8 outputs and of tamper, a 2x0,50+10x0,22 m cable is required
•
For connection of 3 Open Collector outputs, of X (control unit status) and T (tamper
output), other 5x0,22 mm wires are required.