Error Messages
(1) "E1": - This error message is displayed if the temperature sensor fails. The system works in cycles of dehumidification for 30 minutes and
defrosting for 15 minutes. A failed temperature sensor should be replaced.
(2) "E2": This error message is displayed if the humidity sensor fails. The humidity adjusting button will not work. The system works in cycles of
dehumidification for 30 minutes and defrosting for 15 minutes. A failed temperature sensor should be replaced.
(3) "CL": This error message shows when the room temperature is <5°C (41°F). A "CL" code will be displayed and the unit will stop running.
(4) "CH": This error message shows when the room temperature is >38°C (100.4°F). A "CH" code will be displayed and the unit will stop running.
(5) "LO": This error message shows when the room humidity<20%RH. A "LO" code will be displayed and the unit will stop running.
(6)∙"HI":∙∙This∙error∙message∙shows∙when∙the∙room∙humidity≥95%RH.∙∙A∙"HI"∙code∙will∙be∙displayed∙and∙the∙unit∙will∙operate∙normally.