Operating Instructions
Evaluation Unit CMS-E-BR
Evaluation unit CMS-E-BR with 1 read head
Lesekopf 1/
Read Head 1
BK
BU
WH
BN
1
2
3
4
Evaluation unit CMS-E-BR with 4 read heads
Lesekopf 1/
Read Head 1
BK
BU
WH
BN
1
2
3
4
Wiring diagram for CMS-E-BR
UB
-K1
A1
CMS
Rückführkreis/
Feedback Loop
A2
Y1
0V
The following applies to all the illustrations:
Evaluation unit electrically isolated
f
Actuator not in the actuating range
f
No feedback loop connected
f
Figure 2: Wiring diagram for CMS-E-BR
Jumper 2-polig /
Jumper 2-polig /
Jumper 2-pole
Jumper 2-pole
7
8
max. 1 Lesekopf / max. 1 Read Head
Lesekopf 2/
Lesekopf 3/
Read Head 2
Read Head 3
BK
BU
WH
BN
BK
BU
5
6
7
8
12
11
max. 4 Leseköpfe / max. 4 Read Heads
1
2
3
4
5
Lesekopf 1/
Read Head 1
Y2
Jumper 2-polig /
Jumper 2-pole
10
9
16
15
Lesekopf 4/
Read Head 4
WH
BN
BK
BU
WH
BN
10
9
18
17
16
15
6
7
8
12
11
10
9
Lesekopf 2/
Lesekopf 3/
Read Head 2
Read Head 3
8
Sicherheits-
Kontakte/
13
18
17
16
15
Safety
Lesekopf 4/
Contacts
Read Head 4
14
Hilfs-
23
Kontakt/
Auxilliary
Contact
24