• Do not use the unit in the immediate surroundings of a laundry a bath a shower or a swimming pool.
Safety precautions
• Must follow the electric safety regulations when installing the unit.
• If the supply cord is damaged, it must be replaced by the manufacturer or its service agent or a similarly
qualified person in order to avoid a hazard.
• According to the local safety regulations, use qualified power supply circuit and air switch.
• An air switch having a contact separation of at least 3mm in all poles should be fixed in fixed wiring.
• The appliance shall be installed in accordance with national wiring regulation.
• The air switch must have the functions of magnetic tripping and heat tripping in order to prevent short
circuit or overload. Please install the air switch with suitable capacity according to the sheet below.
• Make sure the power supply matches with the requirement of air conditioner. Unstable power supply or
incorrect wiring may result in electric shock, fire hazard or malfunction. Please install proper power supply
cables before using the air conditioner.
• Properly connect the live wire, neutral wire and grounding wire of power socket.
• Be sure to cut off the power supply before proceeding any work related to electric safety.
• Do not put through the power before finishing installation..
Grounding requirement
• The air conditioner is first class electric appliance. It must be properly grounded with specialized grounding
device by a professional. Please make sure it is always grounded effectively, otherwise it may cause electric
shock.
• The yellow-green wire in air conditioner is grounding wire, which can't be used for other purposes.
• The grounding resistance should comply with national electric safety regulations.
Installation of indoor unit
Step 1: recommend the installation location to the client and then confirm it with the client.
Step 2: opening pipe hole
1.
Choose the position of piping hole according to the direction of outlet pipe.
2. Open a piping hole with the diameter of 70 mm on the selected outlet pipe position. In order to drain
smoothly, slant the piping hole on the wall slightly downward to the outdoor side with the gradient of
5-10°.
3. Fix the wall-mounting frame on the wall with tapping screws (ST4.2X25TA) and then check if the frame
is firmly installed by pulling the frame. If the plastic expansion particle is loose, please drill another fixing
hole nearby.