2d. Recessed Mount (Figure 4):
• Cut 15" x 15" square opening in underside of canopy.
• Install accessory mounting plate to front face of fixture
with four # 10 screws provided.
• Remove cover plate knockout plugs (1/2" or 3/4") for
desired conduit diameter.
• Feed flex conduit through canopy opening and secure
to cover plate.
• Connect fixture leads to service leads from flex conduit
in accordance with Section 3 "Wiring."
• Secure cover plate to back of fixture with four #10
screws provided
• Secure accessory mounting plate to underside of
canopy using four #10 toggle bolts (not provided).
Figure 4
#10 SCREWS
Provided
MOUNTING
PLATE
#10 TOGGLE BOLTS
NOT PROVIDED
2e. Surface Mount Conduit Entry (Figure 5):
• Secure fixture to underside of canopy with four #10
toggle bolts (not provided).
• Remove fixture cover plate.
• Remove side conduit plug and replace with customer
supplied conduit on desired side.
• Feed customer supplied electrical wires through
conduit into fixture electrical cavity.
• Make electrical connections inside fixture in
accordance with Section 3 "Wiring."
• Re-install fixture cover plate
CONDUIT PLUGS
Fixture
Cover Plate
Figure 5
15 in. x 15 in.
CUTOUT
#8 SCREWS
Provided
#10 TOGGLE BOLTS
NOT PROVIDED
2f. Surface Mount w/ Beauty Plate (Figure 6):
• Remove cover plate knockout (1/2" or 3/4") for desired
conduit diameter.
• Feed flex conduit through canopy opening and secure
to cover plate.
• Connect fixture leads to service leads from flex
conduit in accordance with Section 3 "Wiring."
• Secure cover plate to top of fixture with four #10
screws provided.
• Secure beauty plate to underside of canopy with four
#10 toggle bolts (not provided).
• Install fixture to beauty plate with four #10 self-drilling
screws provided.
#10 SCREWS
PROVIDED
Figure 6
COVER
PLATE
BEAUTY PLATE
PROVIDED
3
WIRING
NOTE: Make all electrical connections in accordance
with the National Electrical Code and any applicable
local code requirements including grounding.
NOTE: Verify supply voltage matches rating before wiring.
• Verify service leads meet nameplate temperature rating.
• Units are provided with leads exiting the fixture for
connection with service leads and (if ordered) wired dimming.
Wired Dimming
• Connect wired dimming leads per Table 1
• Customer supplied dimming leads 600 volt min.
TABLE 1. Wired Dimming Control Connections
0 VDC (-)
Up to 10 VDC (+)
COVER PLATE
PROVIDED
#10 SELF DRILLING
SCREWS PROVIDED
#10 TOGGLE BOLTS
NOT PROVIDED
Gray Lead
Violet Lead