WARNINGS AND CAUTIONS
•
TO AVOID FIRE, SHOCK OR DEATH, TURN OFF POWER at circuit breaker or fuse and
test that the power is off before wiring!
•
To be installed and/or used in accordance with electrical codes and regulations.
•
If you are not sure about any part of these instructions, consult an electrician.
Features
• Intermateable and compatible with competitive same nose cam-type products - can be
retrofitted to existing locations and power distribution systems
• Shatter and crack proof - high durometer rubber sleeve
• Color coded insulating sleeves - fast and easy phase identification
• Self-compensating for wear - slit and cam in male contact provide spring action for longer usage
• Fast connect/disconnect - twist and pull double cam/guide boss design
• High conductivity - positive, vibration proof connection provided by double cam design
• Wide variety of applications - usable with a wide range of cable sizes and amperage ratings
Hardware Required ( not supplied )
TERMINATION
Threaded stud
• Compression Lug
• 1/2" Flat Washer
• 1/2-13 UNC Hex Nut (5/16" thickness)
• 1/2 Lock Washer
Installation
NOTE: Use the Ampacity Table to select the correct cable size for the application.
C L
Bolt Circle
Ø 2.50
Ø 3.50
(63.5 mm)
(88.9 mm)
Ø 0.28 ( 4 pl. )
90°
Panel Receptacle
1/4-20 Bolts (4)
Align, push together and twist.
Male Connector
FOR CANADA ONLY
For warranty information and/or product returns, residents of Canada should contact Leviton in writing at Leviton Manufacturing of Canada Ltd to the attention of the Quality
Assurance Department, 165 Hymus Blvd, Pointe-Claire (Quebec), Canada H9R 1E9 or by telephone at 1-800-405-5320.
Leviton warrants to the original consumer purchaser and not for the benefit of anyone else that this product at the time of its sale by Leviton is free of defects in materials and workmanship under normal
and proper use for two years from the purchase date. Leviton's only obligation is to correct such defects by repair or replacement, at its option. For details visit www.leviton.com or call 1-800-824-3005. This
warranty excludes and there is disclaimed liability for labor for removal of this product or reinstallation. This warranty is void if this product is installed improperly or in an improper environment, overloaded, misused,
opened, abused, or altered in any manner, or is not used under normal operating conditions or not in accordance with any labels or instructions. There are no other or implied warranties of any kind, including
merchantability and fitness for a particular purpose, but if any implied warranty is required by the applicable jurisdiction, the duration of any such implied warranty, including merchantability and fitness for a
particular purpose, is limited to two years. Leviton is not liable for incidental, indirect, special, or consequential damages, including without limitation, damage to, or loss of use of, any equipment,
lost sales or profits or delay or failure to perform this warranty obligation. The remedies provided herein are the exclusive remedies under this warranty, whether based on contract, tort or otherwise.
17, 19, 22, 23 Series In-Line Panel Receptacles
Rated: 600V, up to 690A continuous current
MOUNTING
Panel Receptacles
• 1/4-20 Bolts (4)
• 1/4-20 Lock Washers (4)
• 1/4-20 Nuts (4)
Bolt Circle
Ø 3.50
(88.9 mm)
(7.1 mm)
C L
30°
Installation
1/4-20
Lock Washers (4)
1/4-20 Nuts (4)
Panel Cutout
Panel Front
Connect
Panel
Female Panel Receptacle
LIMITED 2 YEAR WARRANTY AND EXCLUSIONS
For Technical Assistance Call: 1-800-824-3005 (U.S.A. Only) www.leviton.com
Cable Size: 250 - 750 MCM
WARNINGS AND CAUTIONS
•
Use copper cable only. DO NOT exceed 690A of cable/contact assembly.
Acceptable cable types include: DLO, W & P.
•
Female contacts for taper nose and ball nose devices are not interchangeable.
Taper nose assemblies will not mate properly with ball nose assemblies.
INSTALLATION INSTRUCTIONS
Panel Cutout ( not to scale )
C L
Ø 2.75
(69.9 mm)
Ø 0.28 ( 4 pl. )
(7.1 mm)
C L
2.50
(63.5 mm)
Panel
Receptacle
* NOTE: For 22 and 23 Series Connectors, depress button on sleeve, untwist
and pull apart.
Ampacity Table
Cable Size MCM
60° C Cable
250
340
300
375
350
420
400
455
500
515
600
575
700
630
750
655
C L
Bolt Circle
Ø 2.50
Ø 3.50
(63.5 mm)
(88.9 mm)
2.50
(63.5 mm)
15°
Wiring
1/2" Diameter Washer
Listed Compression Lug
to suit cable size
Panel
Back
Prepare cable end and insert and crimp cable
into lug per manufacturer's requirements
Disconnect
* Depress Button
Panel
PK-A3187-10-02-0A
English
75° C Cable
90° C Cable
405
455
445
505
505
570
545
615
620
690
690
780
755
855
785
885
Ø 0.28 ( 4 pl. )
(7.1 mm)
C L
1/2" Lock Washer
1/2-13 UNC
Hex Nut
- 5/16" thickness
(Tighten nut to
35 ft-lbs.maximum)
© 2017 Leviton Mfg. Co., Inc.