Correction Of Malfunctions; Spare Parts; Spare Parts List - WAGNER SteamStation W1500 P Mode D'emploi

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

W1500 P

11. Correction of Malfunctions

Problem
A. Water is coming out
of the nozzle
B. There is no steam
coming out
C. The steam cap (6)
won't come off
D. Steam flow is erratic;
sometimes it works
well, other times it
does not

12. Spare Parts

The picture that goes with this table can be found on the fold-out page at the
i
beginning of the operating manual.
Pos.
Designation
2, 3
Measurement jug and funnel
4
Towel (3 pcs.)
5
Straight adapter
6
Steam cap
7
Extension tube (2 pcs.)
8, 8a
Floor attachment with swivel adapter
9
Window cleaner
10, 11
Brush and nozzle kit
12
Steam plate
Remedy
➞ The steam cleaner generates a lot of steam. This may
condense as water or water droplets in the steam hose
and can be expelled when used after a period of cooling.
This is normal and not a cause for concern. (see chapter 8)
➞ Check that the hose has not become kinked or blocked
(allow to cool down first). Also check the power supply
and water level.
➞ Descale the steam cleaner (see chapter 10).
To prevent the water tank from calcifying empty the water
tank every time it has been used and use distilled or de-
ionised water
➞ The steam container is still under pressure. Switch off the
device and let it cool down. Press the trigger to release
pressure. (see chapter 9)
➞ Check that all accessory parts are positioned correctly (allow
to cool down first).
➞ Descale the steam cleaner (see chapter 10).
To prevent the water tank from calcifying empty the water
tank every time it has been used and use distilled or de-
ionised water

Spare Parts List

GB
Order No.
2353111
2353106
2351732
2353107
2353109
2353110
2351733
2351731
2353108
21

Publicité