fadini Elpro 12 EVO Mode D'emploi page 15

Masquer les pouces Voir aussi pour Elpro 12 EVO:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Elpro 12 EVO
GB
IMPORTANT: Programming Nyota 115 must be carried out on the rst installation and is retained even in case of a voltage cut o .
!
Any time the position of the limit switches is varied, it is required that gate travel be programmed again in the same way.
IMPORTANT: make sure that gate stops are duly tted to the system in open and closed gate stop positions, whereas the open and
!
close limit switch striking plates are to be xed on to the gear rack in the engaging positions are required.
PROGRAMMING AND GATE TRAVEL SELF-LEARNING
1
st
operation: by the coded key open the release handle until it stops (more than 90°). In this way Nyota 115 is disengaged from the gate. Pull gate
by hand to approximately half way of the total travel. Lock back the operator by closing the handle.
2
nd
operation: gate travel and slowdows learning.
Press and hold button P for 5 seconds then let it go: led LP will start ashing, so indicating that programming phase has started.
rd
3
operation: programming can be carried out either by pressing the dedicated P button, or remotely by the encoded transmitter.
It is most important that both gate stops, in open and close gate positions, be provided as well as the mechanical limit switch striking plates or the
magnetic ones in correspondence with the nal open and closed gate positions as required.
NOTE WELL:
!
During the rst programming phase, the gate must start with the opening operation. Should it not, reverse motor phases and
check the limit switches.
27 28 29
30 31 32 33 34
Output for 2nd
sliding gate
L30 L31 L32 L33
Pulse once:
Nyota 115 will start
opening
LP
At the end of the programming operations, wait for LP led to ash and then go o permanently.
ELECTRONIC CONTROL BOARD FOR NYOTA 115 EVO
Elpro 12 EVO
ELPRO 12 EVO
L1
L4 L5 L6 L7 L8
ON
OFF
1 2 3 4 5 6 7 8 9 10 11 12
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
Starting slowdown in
opening: give one pulse when it is
required that slowdown phase starts
and wait until limit switch reading
point is reached
LP
SETUP
EDGE
A B
ENC
Power
L10
LP
23 24 25 26
16 17 18 19 20 21 22
Pulse once:
Nyota 115 will start
closing
LP
15
LP
5 s
LP
Starting slowdown in
closing: give one pulse when it is
required that slowdown phase starts
and wait until limit switch reading
point is reached
LP

Publicité

Table des Matières
loading

Table des Matières