fadini Elpro 12 EVO Mode D'emploi page 11

Masquer les pouces Voir aussi pour Elpro 12 EVO:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Elpro 12 EVO
GB
All the possible connections to the control board terminals are also described in the instructions sheets of the respective
!
accessories.
NOTE WELL: THE INSTALLATION OF NON FADINI ORIGINAL ACCESSORIES MAY DAMAGE THE PC BOARD. MAKE ALWAYS
!
USE OF FREE CONTACTS FOR THE NO-NC INPUTS. BRIDGE ALL THE NC CONTACTS NOT IN USE.
Accessory
Photocells:
Keyswitch:
Radio contact:
1
2
4
3
5
7
6
8
A
9
S T
O
P
B
F A
D I
N I
24 V - max 3 W
pilot light
output:
Standard limit switch:
Limit switch
HALL EFFECT:
!
ELECTRONIC CONTROL BOARD FOR NYOTA 115 EVO
Electrical connections
1 2
All the NC contacts of the
safety accessories such as
NC
the photocells (the
receiver set) to be series
NC
connected to terminals
1 and 2
NO and NC contacts to be connected to the
3 4 5 6
respective terminals in the key- or
button-operated switches.
All possible con gurations are attached to
the respective command accessories.
By any NO connection to these two terminals the
following is performed, on each pulse given:
3
7
- Opening only: Dip 2=ON and Dip 5=OFF
- Travel reversing
Dip 2=OFF and Dip 5=OFF
- Step by Step operations: Open-Stop-Close-Stop
radio
Dip 2=OFF and Dip 5=ON
contact
- In opening no other command pulse is
accepted. On dwell time and in closing, by each
command pulse, stop and reverse are performed:
Dip 2=ON and Dip 5=ON
3
11
24 V max 3 W output for a light to indicate
gate status:
Light on = gate open
Light o = gate closed
Flashing 0,5 s (fast) = gate closing
Flashing 1 s (normal) = gate closing
IMPORTANT:
Use normally closed limit switches
MOUNT ON THE RIGHT
8 9 10
12 13
24 Vac output max. load:
1 radio receiver
3 pairs of photocells
8 9 10
MOUNT ON THE LEFT
8 9 10
12 13
11
Dip-switch and LED indication
of the various functions
DIP-SWITCH N° 1:
ON: stop in opening and travel reversing in
closing on obstacle removal
OFF: no stop in opening and travel reversing in
1
closing on obstacle detection
L1 green on = no obstacle detected, it goes o
in case an obstacle interposes
L4 red o = no OPEN contact,
it goes on whenever a pulse to open is given
L5 red o = no CLOSE contact,
it goes on whenever a pulse to close is given
L6 green on = STOP contact closed ,
it goes o whenever a pulse to stop is given
DIP-SWITCHES N° 2 and 5:
ON: no reversing and no stop in opening
2
OFF: always stop and reversing in opening
ON: step by step with stop in between
OFF: reversing on radio pulsing
5
L7 red o = no RADIO contact,
it goes on whenever a radio pulse is given
L8 red on = limit sw. closing, o on gate closed
L10 red on = limit sw. open, o on gate open
12 13
L8 red on
limit sw. closing,
o on gate closed
L10 red on
limit sw. open
o on gate open

Publicité

Table des Matières
loading

Table des Matières