4. Install Freestanding Humidifier—Surface
Mount continued
D. Remove the humidifier front cover plate
by removing two screws located at the
base of the cover plate and sliding the
cover up and off of the two plastic tabs at
the top of the unit. (Fig. C,D)
E. Attach 1/4 (0.6cm) water line at top of
humidifier. (Fig. E)
F. Attach 1/2" (1.3cm) drain line at bottom
of humidifier.
Note: Water supply line and drain line
should be routed at the back side of the unit
between the mounting bracket and humidifi-
er chassis. Attach to humidifier prior to step
Step G below.
G. Slide the humidifier through the bracket
and attach at the side mounting locations.
(Fig. G,H)
H. Re-install the humidifier front cover plate
by sliding the cover over the two top plas-
tic tabs and securing at the bottom of the
humidifier with two screws. (Fig. I, J)
I. Plug in power/control wire to Wine
Guardian unit as shown at main control
panel. (Fig. K)
J. Proceed to Step 6 - Controller set-up.