TROUBLESHOOTING GUIDE

Symptom
Burner will not light
Burner will not stay lit
Slow to heat up
Gas Odor
Burner not working well / lazy
or yellow flame
Control panel LED lights not
working
Nuisance clicking of side
burner
Check
Gas supply not on / shutoff valve closed
LP gas cylinder empty
Power cord not plugged in, or no power to receptacle, or blown
fuse
Low gas pressure to unit
Burner ports near igniter are obstructed or dirty
Burner cap not installed correctly on base
Defective or clogged burner valve
Incorrect orifice or clogged orifice
Igniter defective (not sparking)
Defective regulator or regulator installed improperly
Burner ports obstructed or dirty
Vent plugged on regulator or regulator installed improperly
Windy conditions
Low gas pressure
Low gas pressure or low LP cylinder
Burner ports are obstructed or dirty
Defective or clogged burner valve
Incorrect orifice or clogged orifice
Burner went out or did not light
Loose or broken gas line
Ruptured pressure regulator
Burner cap not installed correctly on base
Poor combustion, air-fuel mixture not adjusted properly
Obstructed/dirty burner ports
Burner ports are obstructed or dirty, check for spider webs
Poor combustion, air-fuel mixture not adjusted properly
Gas pressure incorrect / incorrect regulator
Orifice sized incorrectly for gas type
Power cord not plugged in, or no power to receptacle
Check fuse on electrical box.
Windy conditions
Flame too low
Food debris on electrode