Gas Connections - hestan AGB121-NG Mode D'emploi

Gril de plein air
Masquer les pouces Voir aussi pour AGB121-NG:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

GAS CONNECTIONS

GAS SUPPLY
The local gas authority or supplier should be consulted at the installation planning stage in order
to establish the availability of an adequate supply of gas (NG or LP). If it is a new installation,
EN
have the gas authorities or supplier check the meter size and piping to assure that the unit is
supplied with the necessary amount of gas supply and pressure to operate the unit(s).
Gas connections should be made by a qualified plumber, or your professional outdoor appliance
installer.
All fixed (non-mobile) appliances must be fitted with an accessible upstream gas shutoff valve as
a means of isolating the appliance for emergency shut off and for servicing.
Make certain new piping and connections have been made in a clean manner and have been
purged so that piping compound, chips, etc. will not clog regulators, valves, orifices, or burners.
Use pipe joint compound / thread sealant approved for natural and LP gases.
NEVER CONNECT THE SIDE BURNER TO AN UNREGULATED GAS SUPPLY. Before
proceeding, ensure the appliance is fitted for Natural or Liquid Propane gas. Connecting to an
improper gas type will result in poor performance and increased risk of damage or injury. Gas
type and gas consumption (BTU per hour) for each burner type is shown on the rating label
affixed to the underside of the drip tray.
Installation of this cooking appliance must be made in accordance with local codes. In the
absence of local codes, this unit should be installed in accordance with the National Fuel Gas
Code No. Z223.1/ NFPA 54 , Natural Gas and Propane Installation code CSA B149-1, or Propane
Storage and Handling Code B149.2.
NOTE: See rating label for manifold pressure for the type of gas of your appliance.
CONVERSION KITS
Gas conversion kits are available from your Hestan dealer should you need to convert an LP unit
to NG, or vice-versa.
HIGH ALTITUDE KITS
If you live in a high altitude area, 2,000 ft. (610 m) or more above sea level, your side burner will
require different orifices for proper combustion and performance. High altitude kits are available
through Hestan Customer Service. Please have your model and serial number information ready
when you call.
15
©2016 Hestan Commercial Corporation

Publicité

Chapitres

Table des Matières
loading

Table des Matières