TEMPERATURE CONTROL

The temperature is controlled by a thermostat which is
located above the front ventilation louvers, just below the
door. The thermostat is factory-set to maintain the internal
temperature between 2 and 8°C (35.6 and 46.4°F). The
thermostat normally displays the temperature inside the
cabinet. The default setting is 2°C.
To change the set temperature,
1. Press and hold the
appears on the screen.
2. Release the button and press it again to confirm the "0" command.
3. Press the UP or DOWN buttons until you see the parameter "St" on the screen.
set
4. Press the
button again to enter that parameter.
5. With the UP and DOWN buttons choose the desired operating temperature. (NOTE: Only
temperatures from 2 to 8°C are permitted.)
set
6. Press
again to confirm the temperature.
7. Wait 1 minute without touching any button while the unit accepts the changes. It will then start
running normally.

ALARM SETTINGS

Your refrigerator is designed to sound an alarm if the internal temperature rises above15°C or falls below
0°C.
An alarm will also sound if the door is left open for more than 2 minutes.
To stop an alarm when it is sounding, press the

ENERGY-SAVING MODE

To save energy by limiting the length of operation time of the fan motors and compressor and by turning
off the interior light, you can put the refrigerator into Energy-Saving mode by pressing the UP arrow
(ECO) for 3 seconds. The display will show " EnS" when this mode is active. To deactivate the Energy-
Saving mode, press the UP arrow again and hold it for at least 3 seconds.

LIGHTING

LED lighting surrounds the glass on the interior side of the door. Additionally, the header panel above the
door is backlit.
Cabinet lighting is designed to function continuously or may be controlled with a switch, located inside the
unit to the left of the internal fan in the ceiling. See Wiring Diagram, page 9. Putting the refrigerator into
Energy-Saving mode (see section above) will also turn off the interior lighting.
NOTES:
If the unit is unplugged, or power is lost or turned off, you must wait 3 to 5 minutes before
restarting the unit. If you attempt to restart before this time delay, the unit will not start.
When you use the unit for the first time or restart the unit after it has been shut off for a long
time, allow a few hours for the interior temperature to normalize.