Briteq LD SMART DIM Mode D'emploi page 8

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

ENGLISH
SETUP
Choosing the DMX-profile for each zone
You can connect different kinds of DMX projectors to each of the 6 zones. This means that for each zone
you can choose a different DMX-profile. The dmx start address of each zone is specified in the specifications
at the end of the manual.
1. Set Dipswitch 1 to "on".
2. Select a zone from 1 to 6 (you can select more than one zone at the same
time) , they must be selected within 1.5s.
3. Turn the jog wheel to change the type of fixture for the selected zone. The
related LED button will show the channel mode by changing the color
corresponding to the diagram below:
Profile
RGB+D (0-255)
RGB+D (0-190)
RGBW
WW/CW
DIMMER
 RGB+D (0-255): The rgb + dimmer profile is used when the fixture has a dimmer channel
without strobe and music function. In this case the maximum value for the dimmer is 255. If
the user selects this profile for a fixture with strobe and music function, he will be able to select
these extra functions. He simply turns the jog wheel to values above 190 (see DMX chart for
details).
 RGB+D (0-190): The maximum value for the dimmer channel will be limited to 190. On
projectors with strobe and music function you can exclude these functions by choosing this
profile. Please refer to the dmx chart of the product in the manual for more information.
 RGB: This profile only supports RGB fixtures without a dimmer channel. The dimmer value will
be recalculated on the three colors
 RGBW: This profile only supports RGBW fixtures without dimmer channel. The dimmer value
will be recalculated on the four colors.
 WWCW: This profile only supports Warm White / Cold White fixtures without dimmer channel.
The dimmer value will be recalculated on both colors.
 Dimmer: This profile is only used for traditional lighting or 1CH LED fixtures.
4. Once all zones are set up, set the dipswitch 1 to off.
Master mode:
Dip #2=on)
(
If there is only one LD-SMART DIM, it must be set in master mode. Set the Dip
Switch 2 to "on".
If there is more than one controller on the bus, set one of them as the master and all
others as slaves. The configuration should always have at least one master.
Slave units have the Dipswitch 2 in "off" position.
Service light mode Setup:
The on/off function has 2 different modes:
MODE1:
Press the jog wheel for at least 1second: all zones are switched on/off together.
MODE2:
Press the jog wheel shortly: only the output of the "preselected" zones that were preselected in a setup
procedure will be switched on/off. (in other words: you can determine yourself which zones will be switched
on/off)
BRITEQ
®
Button color
YELLOW
RGB
GREEN
CYAN
BLUE
MAGENTA
CH
RED
4
4
3
4
2
1
6/44
OPERATION MANUAL
LD-SMART DIM

Publicité

Table des Matières
loading