MAINTENANCE

With prolonged use of the appliance, it is indispensable to carry out regular maintenance for the safe functioning of the
appliance; we therefore reccomend drawing up a contract for after slaes service.
Maintenance must be done only by specialized personnel, observing the norms in force and our indications.
SPARE PARTS Fig.A
It is possible to substitute parts such as the valve, the piezoelectric lighter or gas pipes very simply.
To substitute the parts, procede as follows:
Valve: after removing the front panel, unscrew the screwed fittings (04-05) of the gas connections and take out the
bulb of the thermostat, then substitute the faulty parts, installing the new ones.
To substitute the thermocouple, unscrew the fitting (06) of the valve and substitute the element.
The spark plug (07) must be unscrewed and substituted.

INSTRUCTIONS FOR USE

Attention! In the event that smoke is given off, when the appliance is started up, it is necessary to let the installation
function without being used, for approximately an hour or until the smell disappears.

LIGHTING THE MAIN BURNER

Lighting the pilot burner

Push and turn the thermostat knob (01) into position
Keeping the knob pushed down, press the piezo button (03) repeatedly. The flame lights automatically and can be seen
trough the inspection hole in the front panel. After lighting, hold the knob down for another 5-10 seconds, to allow the
thermocouple to warm up, then release it. The flame may go out, in which case it is necessary to repeat the procedure.

Lighting the main burner and regulating the temperature

After releasing the knob, the gas goes into the safety valve. Turning the graduated knob from 60 to 300° C, the gas goes
to the main burner whcih then lights.

Putting out the main burner

Turn the knob into position
Turning off the appliance
Push and turn the knob into position "0". This command blocks the gas supply to both the main burner and the pilot
burner.

DRIP PAN (11)

The drip pan must be checked regularly and emptied before getting full. In any event, the pan must be cleaned after

switching off the appliance.

GB
;only the flame of the pilot burner remains lit.