sigfox TEMP- Guide utilisateur / User guide version V2.0.0
321
1
FR
322
1
323
1
324
4
EN
325
1
326
4
327
1
328
4
329
1
330
4
331
1
332
1
333
1
A consistency check will be performed at the time of the registration of the settings via the AT&W command. If one of the following conditions
is verified, the command will return «W»:
• Period of transmission = 0 (register 301) and no active threshold (registers 321 and 323)
• Two active thresholds (registers 321 and 323), and the value of the high threshold is less than the value of the low threshold.
Configuring the event behaviour of the
internal sensor
Configuration of the external sensor
Configuring the event behaviour of the
external sensor
High threshold value of the internal
sensor
Value of the high threshold hysteresis
of the internal sensor:
Low threshold value of the internal
sensor
Value of the low threshold hysteresis of
the internal sensor
High threshold value of the external
sensor
Value of the high threshold hysteresis
of the iexternal sensor:
Low threshold value of the external
sensor
Value of the low threshold hysteresis of
the exterbal sensor
Acquisition period
Super-sampling factor
Hexadecimal Default 0x03
Bits 0 to 1: Threshold triggering
• 0 = None
• 1 = Low only
• 2 = High only
• 3 = Low and High
Bits 2 to 7: Reserved
Hexadecimal See details of register 320
Hexadecimal See details of register 321
Decimal
Default: 300
Min/max: -550 to 1200 (signed value)
Units: tenth of °C
Decimal
Default: 10
Min/max: 0 of 255 (Unsigned value)
Unit: tenth of °C
Decimal
Défaut: 300
Min/max: -550 à 1200 (Unsigned value)
Unit: tenth of °C
Decimal
Default: 10
Min/max: 0 à 255 (Unsigned value)
Unit: tenth of °C
Decimal
Dfaut: 300
Min/max: -550 à 1200 (Unsigned value)
Unit: tenth of °C
Decimal
Default: 10
Min/max: 0 to 255 (Unsigned value)
Unit: tenth of °C
Decimal
Default: 300
Min/max: -550 à 1200 (Unsigned value)
Unit: tenth of °C
Decimal
Default: 10
Min/max: 0 à 255 (Unsigned value)
Unit: tenth of °C
Decimal
Default: 10
Min/max : 1 à 255
Unité:
x 1minute if S306=1
x 10 secondes if S306=2
Decimal
Default: 5
Min/max: 1 à 10
Unit: aucune
Page
60
of 79