Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Liens rapides

sigfox TEMP
Ready-To-Use Temperature Device
Ce Guide utilisateur s'applique à partir des versions logicielles suivantes :
This User Guide applies from the following firmware versions:
Version RTU : V01.01.01
Version APP : V01.03.03
adeunis ®
283 rue Louis Néel - Parc Technologique Pré Roux
38920 CROLLES - France
Tel. : +33 (0)4 76 92 07 77 - Fax : +33 (0)4 76 04 80 87
www.adeunis.com
sales@adeunis.com
Guide utilisateur / User Guide
Version 2.0.0

Publicité

Table des Matières
loading

Sommaire des Matières pour ADEUNIS sigfox TEMP

  • Page 1 TEMP Ready-To-Use Temperature Device Guide utilisateur / User Guide Version 2.0.0 Ce Guide utilisateur s’applique à partir des versions logicielles suivantes : This User Guide applies from the following firmware versions: Version RTU : V01.01.01 Version APP : V01.03.03 adeunis ®...
  • Page 2 Ninguna parte de este documento puede ser reproducida o transmitida (en fotocopias electrónico o en papel, o) sin el acuerdo adeunis®. Este documento puede ser modifi cada sin previo aviso. Todas las marcas comer- ciales mencionadas en esta guía son el tema de los derechos de propiedad intelectual.
  • Page 3: Table Des Matières

    TEMP- Guide utilisateur / User guide version V2.0.0 TABLE DES MATIERES FRANCAIS INFORMATIONS PRODUIT ET REGLEMENTAIRES PRESENTATION DU PRODUIT 1.1. Description générale 1.2. Encombrement 1.3. Carte électronique 1.4. Spécifications Techniques 1.4.1 Caractéristiques générales 1.4.2 Autonomie 1.4.3 Caractéristiques des sondes FONCTIONNEMENT DU PRODUIT 2.1.
  • Page 4 TEMP Guide utilisateur / User guide version V2.0.0 ENGLISH PRODUCTS AND REGULATORY INFORMATION PRODUCT PRESENTATION 1.1. General description 1.2. Dimensions 1.3. Electronic board 1.4. Technical Specifications 1.4.1 General characteristics 1.4.2 Autonomy 1.4.3 Sensor characteristics PRODUCT OPERATION 2.1. Global operation 2.1.1 PARK MODE...
  • Page 5: Francais

    TEMP- Guide utilisateur / User guide version V2.0.0 FRANCAIS Page of 79...
  • Page 6: Informations Produit Et Reglementaires

    Ce document et l’utilisation de toute information qu’il contient, est soumis à l’acceptation des termes et conditions adeunis®. adeunis® ne donne aucune garantie sur l’exactitude ou l’exhaustivité du contenu de ce document et se réserve le droit d’apporter des modifi cations aux spécifi cations et descriptions de produit à tout moment sans préavis.
  • Page 7: Déclaration Ue De Conformité

    TEMP- Guide utilisateur / User guide version V2.0.0 Déclaration UE de Conformité Nous adeunis 283 rue LOUIS NEEL 38920 Crolles, France 04.76.92.01.62 www.adeunis.com Déclarons que la DoC est délivrée sous notre seule responsabilité et fait partie du produit suivant : Modèle produit :...
  • Page 8 notifi...
  • Page 9: Recommandations Environnementales

    TEMP- Guide utilisateur / User guide version V2.0.0 RECOMMANDATIONS ENVIRONNEMENTALES Tous les matériaux d’emballage superfl us ont été supprimés. Nous avons fait notre possible afi n que l’emballage soit facilement séparable en trois types de matériaux : carton (boîte), polystyrène expansible (matériel tampon) et poly- éthylène (sachets, feuille de protection en mousse).
  • Page 10: Recommandations D'usage

    TEMP Guide utilisateur / User guide version V2.0.0 RECOMMANDATIONS D’USAGE • Avant d’utiliser le système, vérifi ez si la tension d’alimentation fi gurant dans son manuel d’utilisation corres- pond à votre source. Dans la négative, consultez votre fournisseur. •...
  • Page 11: Presentation Du Produit

    NOTE IMPORTANTE : le démarrage du sigfox TEMP ne peut se faire que grâce à un aimant. Description : • Le sigfox TEMP d’adeunis® est un appareil radio prêt à l’emploi permettant de mesurer des températures et de les envoyer sur un réseau sans-fil.
  • Page 12: Encombrement

    TEMP Guide utilisateur / User guide version V2.0.0 1.2. Encombrement Valeurs en millimètres 49,50 1.3. Carte électronique 49,50 Antenne interne Module RF Batterie interne Protocole sigfox 49,50 Port USB pour configuration produit Page of 79...
  • Page 13: Spécifications Techniques

    TEMP- Guide utilisateur / User guide version V2.0.0 1.4. Spécifications Techniques 1.4.1 Caractéristiques générales Paramètres Valeur Tension d’alimentation 3.6V nominal Courant maximum 90mA Alimentation Version pile amovible : SAFT LS14500 Température de fonctionnement -25°C / +70°C Dimensions 105 x 50 x 27mm...
  • Page 14: Fonctionnement Du Produit

    TEMP Guide utilisateur / User guide version V2.0.0 2. FONCTIONNEMENT DU PRODUIT 2.1. Modes de fonctionnement NOTE IMPORTANTE : adeunis® utilise le format de données Big-Endian MODE PARC Présence d’un aimant sur le produit >6s Envoi commande Présence d’un aimant sur lien série...
  • Page 15: Mode Repli

    TEMP- Guide utilisateur / User guide version V2.0.0 2.1.4 Mode REPLI Le produit entre dans ce mode très basse consommation suite à la détection d’un niveau de batterie trop faible. Dans ce mode le produit se réveille toutes les 5 secondes pour faire clignoter 2 fois la LED rouge.
  • Page 16: Transmission Sur Dépassement De Seuil

    TEMP Guide utilisateur / User guide version V2.0.0 2.2.2 Transmission sur dépassement de seuil Le produit permet la détection de dépassement de seuil (haut et bas) pour chaque capteur selon le schéma suivant : Produit en veille Période sur échantillon-...
  • Page 17 TEMP- Guide utilisateur / User guide version V2.0.0 Explication des seuils et hystérésis : La période de scrutation des capteurs est égale à la période d’acquisition (registre 332) divisée par le facteur de sur-échantillonnage (registre 333). Les paramètres associés à ce mode de fonctionnement sont : •...
  • Page 18 TEMP Guide utilisateur / User guide version V2.0.0 Exemple : Registre Codage de la Valeur Résultat valeur S301 Décimal Mode évènementiel S320 Hexadécimal 0xD0 Identifiant du capteur interne mis à 0xD S322 Hexadécimal 0x80 Identifiant du capteur externe mis à 0x8 S321 Hexadécimal...
  • Page 19: Transmission D'une Trame De Vie Journalière

    TEMP- Guide utilisateur / User guide version V2.0.0 2.2.3 Transmission d’une trame de vie journalière En mode évènementiel (seuil), le produit pourrait ne jamais envoyer de trames de données. Ainsi, pour s’assurer du bon fonctionnement de celui-ci une trame de vie est transmise régulièrement selon le schéma suivant : En mode périodique (registre 301 différent de 0), il n’y a pas d’émis-...
  • Page 20: Fonctionnement Des Leds

    TEMP Guide utilisateur / User guide version V2.0.0 2.3. Fonctionnement des LEDs Mode Etat Led Rouge Etat Led Verte Emission de trame (mode TEST seulement) Allumé pendant l’émission Réception de trame (mode TEST seulement) Allumé pendant la réception d’une trame de...
  • Page 21: Configuration Du Produit

    TEMP- Guide utilisateur / User guide version V2.0.0 CONFIGURATION DU PRODUIT La configuration du produit se fait au moyen du connecteur USB. Cette connexion permet de communiquer avec le produit par un port com virtuel et d’envoyer des commandes AT pour modifier les paramètres du produit.
  • Page 22: Mode Commande

    TEMP Guide utilisateur / User guide version V2.0.0 3.2. Mode commande Utiliser un terminal port COM pour communiquer avec le produit. Nous utilisons le soft terminal port COM HERCULES disponible en télécharge- ment gratuit à l’adresse suivante : http://www.hw-group.com/products/hercules/index_en.html •...
  • Page 23: Commande At

    TEMP- Guide utilisateur / User guide version V2.0.0 3.3. Commande AT Une commande débute avec les 2 caractères ASCII : « AT », suivis d’un ou plusieurs caractères et données (voir ci-après la syntaxe des com- mandes AT disponibles sur le modem).
  • Page 24: Description Des Registres

    TEMP Guide utilisateur / User guide version V2.0.0 3.4. Description des registres A la mise sous tension le produit fonctionne selon la dernière configuration sauvegardée (configuration usine si c’est la première mise sous tension, ou si cette configuration n’a pas été changée).
  • Page 25 TEMP- Guide utilisateur / User guide version V2.0.0 Configuration du comportement événe- Hexadécimal Défaut 0x03 mentiel du capteur interne Bits 0 à 1 : Déclenchement sur seuil • 0 = Aucun • 1 = Bas uniquement • 2 = Haut uniquement •...
  • Page 26: Registres Réseau

    TEMP Guide utilisateur / User guide version V2.0.0 3.4.2 Registres réseau La liste des registres ci-dessous permet de modifier les paramètres réseau du produit. Cette liste est accessible en mode PROVIDER suite à l’exé- cution de la commande ATT63 PROVIDER.
  • Page 27: Description Des Trames

    TEMP- Guide utilisateur / User guide version V2.0.0 4. DESCRIPTION DES TRAMES 4.1. Trames montantes (uplink) Toutes les trames montantes du produit vers le réseau (uplink) ont toujours une taille de 11 octets. 4.1.1 Octets fixes Les deux premiers octets de la trame sont systématiquement dédiés pour indiquer le code de la trame et le statut comme présenté ci-dessous :...
  • Page 28: Trames D'information Sur La Configuration Du Produit

    TEMP Guide utilisateur / User guide version V2.0.0 4.1.2 Trames d’information sur la configuration du produit Lors du passage en mode exploitation (sortie du mode PARC ou COMMANDE), les trames suivantes (0x10 à 0x12) représentant la configura- tion applicative du produit sont transmises :...
  • Page 29: Trame D'information Sur La Configuration Du Réseau

    TEMP- Guide utilisateur / User guide version V2.0.0 2 à 3 5 à 6 Code Status PAYLOAD 0x12 Cf Status S328 S329 S330 S331 0x12 0xA2 0x0190 0x14 0xFED4 0x05 Description de la trame : • Octets 2 à 3 : registre 328, seuil haut du capteur externe, octet de poids fort en premier •...
  • Page 30: Trame De Réponse À Une Demande De Valeur De Registre(S)

    TEMP Guide utilisateur / User guide version V2.0.0 • La valeur spéciale 0x8000, équivalente à -3276,8 °C est retournée en cas de défaut du capteur. • Octet 5 : o Bits 0 à 3 : 0 : inconnu/absent/erreur 1 : Sonde CTN externe : inconnu 2 : Sonde CTN externe : FANB57863-400-1 o Bits 4 à...
  • Page 31: Synthèse Des Conditions D'envoi Des Trames Montantes

    TEMP- Guide utilisateur / User guide version V2.0.0 Description de la trame : • Octet 2 : o Bits 0 à 3 : 0 : inconnu/absent/erreur 1 : Sonde CTN interne B57863S0321F040 o Bits 4 à 7 : identifiant de l’utilisateur définie dans le registre 320 •...
  • Page 32: Trames Descendantes (Downlink)

    (RX window) pendant maximum 30 secondes, conformément au schéma ci-dessous : La configuration de la politique d’envoi de demande d’acquittement dans le produit adeunis® diffère selon que le produit est en mode pério- dique ou évènementiel : •...
  • Page 33: Trame De Demande De La Configuration Du Produit

    TEMP- Guide utilisateur / User guide version V2.0.0 4.2.1 Trame de demande de la configuration du produit Cette trame permet de faire savoir au produit via le réseau qu’il doit réémettre la trame montante de configuration du produit (0x10).
  • Page 34: Trame De Mise À Jour De La Valeur De Registres Spécifiques

    TEMP Guide utilisateur / User guide version V2.0.0 4.2.4 Trame de mise à jour de la valeur de registres spécifiques Cette trame (0x41) permet via le réseau de modifier sur le produit les valeurs des registres demandés. Trame 0x41 : …...
  • Page 35: Demarrage

    6 secondes de sorte à confirmer le démarrage du produit. Lorsque l’aimant est bien détecté, la LED verte s’allume prendant 1 seconde. Une fois que le sigfox TEMP valide son démarrage, il émet ses trames de statut puis, après le temps de la période d’émission défini, une trame de donnée.
  • Page 36: Fermeture Du Boîtier

    TEMP Guide utilisateur / User guide version V2.0.0 5.3. Fermeture du boîtier Une fois les étapes précédentes effectuées, vous pouvez fermer le boiter du sigfox TEMP. Procédure : Assurez-vous que le joint d’étanchéité est bien en place sur la semelle Clipsez la carte électronique sur la semelle du boîtier.
  • Page 37: Installation Et Utilisation

    TEMP- Guide utilisateur / User guide version V2.0.0 6. INSTALLATION ET UTILISATION 6.1. Positionnement correct des émetteurs Deux règles sont primordiales pour une optimisation des portées radio. • La première consiste à positionner votre produit le plus haut possible.
  • Page 38: Partie Dégagée

    TEMP Guide utilisateur / User guide version V2.0.0 Pour retirer celui-ci, tirer vers le bas sur le levier jusqu’à ce que les Ergots ergots de blocage soient face à une partie dégagée et retirer le levier Partie dégagée 6.2.2 Fixation par vis Le produit est livré...
  • Page 39: Fixation Rail-Din

    TEMP- Guide utilisateur / User guide version V2.0.0 6.2.3 Fixation Rail-DIN Ce système, intégré au boîtier, permet de fixer le produit sur un rail standard de 35mm • Pour installer le boîtier, placer les inserts supérieurs sur le rail et abaisser le produit pour le clipser •...
  • Page 40: English

    TEMP- Guide utilisateur / User guide version V2.0.0 ENGLISH Page of 79...
  • Page 41: Products And Regulatory Information

    APP Version: V01.03.03 DISCLAIMER This document and the use of any information contained therein, is subject to the acceptance of the adeunis® terms and conditions. They can be downloaded from www.adeunis.com. adeunis® makes no warranties based on the accuracy or completeness of the contents of this document and reserves the right to make changes to specifi...
  • Page 42: Eu Declaration Of Conformity

    TEMP- Guide utilisateur / User guide version V2.0.0 EU Declaration of Conformity adeunis 283 rue LOUIS NEEL 38920 Crolles, France 04.76.92.01.62 www.adeunis.com Declare that the DoC is issued under our sole responsibility and belongs to the following product: Apparatus model/Product:...
  • Page 43 valid.
  • Page 44: Environmental Recommendations

    TEMP- Guide utilisateur / User guide version V2.0.0 ENVIRONMENTAL RECOMMENDATIONS All superfl uous packaging materials have been eliminated. We have done everything possible to make it easy to separate the packaging into three types of materials: cardboard (box), expanded polystyrene (fi ller material) and polyethylene (packets, foam protective sheets).
  • Page 45: Recommandations Regarding Use

    TEMP- Guide utilisateur / User guide version V2.0.0 RECOMMANDATIONS REGARDING USE • Before using the system, check that the power supply voltage shown in the user manual corresponds to your supply. If it doesn’t, please consult your supplier. •...
  • Page 46: Product Presentation

    • This product meets the needs of users who require to remotely monitor internal and external temperatures of storage rooms, meeting rooms, cold rooms, etc. • The use of the sigfox protocol allows the user to integrate the sigfox TEMP into any network that is already deployed. • The sigfox TEMP is fitted with internal and external probes.
  • Page 47: Dimensions

    TEMP- Guide utilisateur / User guide version V2.0.0 1.2. Dimensions Values in millimetres 49,50 1.3. Electronic board 49,50 Internal antenna RF module Internal battery sigfox protocol 49,50 USB port for product configuration Page of 79...
  • Page 48: Technical Specifications

    TEMP- Guide utilisateur / User guide version V2.0.0 1.4. Technical Specifications 1.4.1 General characteristics Parameters Value Supply voltage Nominal 3.6V Maximum current 90mA Power supply: Removable battery version: SAFT LS14500 Working temperature -25°C / +70°C Dimensions: 105 x 50 x 27mm...
  • Page 49: Product Operation

    TEMP- Guide utilisateur / User guide version V2.0.0 2. PRODUCT OPERATION 2.1. Global operation Important: adeunis® use the most significant byte first format. The product has several operating modes: PARK MODE Presence of a magnet Command sen- on the product >6s...
  • Page 50: Repli Mode

    TEMP- Guide utilisateur / User guide version V2.0.0 2.1.4 REPLI mode The product enters this very low consumption mode following the detection of a level of battery that is too low. In this mode the product wakes up every 5 seconds to make the red LED flash twice.
  • Page 51: Transmission Over Threshold

    TEMP- Guide utilisateur / User guide version V2.0.0 2.2.2 Transmission over threshold The product allows the detection threshold overrun (upper and lower) for each sensor according to the following diagram: Product in standby Sampling period reached? Internal tempe- rature measurement...
  • Page 52 TEMP- Guide utilisateur / User guide version V2.0.0 Explanation of thresholds and hysteresis: high threshold High threshold - high threshold hysteresis Sensor value Low threshold + low threshold hysteresis Low threshold Low alarm enabling Low alarm disabling High alarm enabling High alarm disabling The period of monitoring by the sensors is equal to the period of acquisition (register 332) divided by the super-sampling factor (register 333).
  • Page 53 TEMP- Guide utilisateur / User guide version V2.0.0 E.g.: Registre Codage de la valeur Valeur Résultat S301 Décimal Event mode S320 Hexadécimal 0xD0 Identifier of the internal sensor set to 0xD S322 Hexadécimal 0x80 Identifier of the external sensor set to 0x8 S321 Hexadécimal...
  • Page 54: Transmission Of A Daily Keep Alive Frame

    TEMP- Guide utilisateur / User guide version V2.0.0 2.2.3 Transmission of a daily Keep Alive frame In the event (threshold) mode only, it is possible that the product would never send data frames. So to be sure that it is working properly a Keep...
  • Page 55: Operation Of The Leds

    TEMP- Guide utilisateur / User guide version V2.0.0 2.3. Operation of the LEDs Mode LED red state LED green state Transmission of frame (TEST mode only) ON during the transmission cycle Reception of frame (TEST mode only) ON during the reception of a downlink frame...
  • Page 56: Device Configuration

    TEMP- Guide utilisateur / User guide version V2.0.0 DEVICE CONFIGURATION The device can be configured using the USB connector. This connection allows you to communicate with the device via a virtual com port and to transmit AT commands in order to modify the parameters of the device.
  • Page 57: Command Mode

    TEMP- Guide utilisateur / User guide version V2.0.0 3.2. Command mode Use a COM port terminal in order to communicate with the device. We use the HERCULES COM port soft terminal available to download for free by clicking on the following link: http://www.hw-group.com/devices/hercules/index_en.html •...
  • Page 58: At Commands

    TEMP- Guide utilisateur / User guide version V2.0.0 3.3. AT commands A command starts with 2 ASCII characters: “AT”, followed by one or more characters and data (see the list below for the syntax of AT com- mands available on the modem).
  • Page 59: Description Of The Registers

    TEMP- Guide utilisateur / User guide version V2.0.0 3.4. Description of the registers On switching on the product works according to the last saved configuration (Factory Configuration if it is the first start, or if this configuration has not been changed). Commands such as Modification TTY<n>=<M> or ATR allow you to change the content of the registers: <n> repre- senting the number of the register and <m>...
  • Page 60 TEMP- Guide utilisateur / User guide version V2.0.0 Configuring the event behaviour of the Hexadecimal Default 0x03 internal sensor Bits 0 to 1: Threshold triggering • 0 = None • 1 = Low only • 2 = High only •...
  • Page 61: Network Registers

    TEMP- Guide utilisateur / User guide version V2.0.0 3.4.2 Network registers The list of registers below allows you to change the behaviour of the product application. This list is accessible in Provider mode following execution of the ATT63 Provider command.
  • Page 62: Description Of The Frames

    TEMP- Guide utilisateur / User guide version V2.0.0 4. DESCRIPTION OF THE FRAMES 4.1. Uplink frame All of the uplink frames of the product to the network (uplink) always have a size of 11 bytes. 4.1.1 Fixed bytes The first two bytes of the frame are systematically dedicated to indicate the frame code and the status as presented below:...
  • Page 63 TEMP- Guide utilisateur / User guide version V2.0.0 • Byte 3: register 301, periodicity of transmission (periodic mode), expressed in tens of minutes • Byte 4: register 320, configuration of the internal sensor • Byte 5: register 321, configuration of the events of the internal sensor •...
  • Page 64: Frame Of Information On The Network Configuration

    TEMP- Guide utilisateur / User guide version V2.0.0 In the example in grey this gives: • Bytes 2 to 3=0x0190: register 328, the value of the high threshold of the external sensor is: 400/10=40°C • Byte 4=0x14: register 329, register 329, the value of the hysteresis of the high threshold of the external sensor is: 20/10=2°C •...
  • Page 65: Reply Frame To A Register Value Request In A Downlink Frame

    TEMP- Guide utilisateur / User guide version V2.0.0 • Bytes 6 to 7: Value measured on the internal sensor • Signed value on 16 bits, • Expressed in tenths of degrees, • Most significant byte first • The special value 0x8000, equivalent to -3276, 8°C is returned in the event of a fault in the sensor.
  • Page 66: Summary Of The Conditions Of The Transmission Of The Uplink Frames

    TEMP- Guide utilisateur / User guide version V2.0.0 Description of the frame: • Byte 2: o Bits 0 to 3: 0: unknown/absent/error 1: CTN internal sensor B57863S0321F040 o Bits 4 to 7: The user identifier defined in register 320 •...
  • Page 67: Downlink Frames

    (RX window) for a maximum of 30 seconds, in accordance with the diagram below: The configuration of the sending policy of the acknowledgement request in the adeunis® product differs according to whether the product is in periodic or event mode: •...
  • Page 68: Product Configuration Request Frame

    TEMP Guide utilisateur / User guide version V2.0.0 4.2.1 Product configuration request frame This frame allows to inform the product via the network that it must resend the product configuration uplink frame (0x10). Code PAYLOAD 0x01 4.2.2 Network configuration request frame This frame allows to inform the product via the network that it must resend the network configuration uplink frame (0x20).
  • Page 69: Frame For Updating The Value Of Specific Registers

    TEMP- Guide utilisateur / User guide version V2.0.0 4.2.4 Frame for updating the value of specific registers This frame (0x41) allows to change the value of requested registers. … Code PAYLOAD CONFID2 value CONFID2 value 0x41 CONFID1 CONFID1 value CONFID2 …...
  • Page 70: Start-Up

    6 seconds so as to confirm the start-up of the product. When the magnet is well detected, the green LED lights up for 1 second. Once the sigfox TEMP unit validates its start-up, it immediately transmits status frames followed by a data frame (according the defined periodi- city).
  • Page 71: Closing The Casing

    TEMP- Guide utilisateur / User guide version V2.0.0 5.3. Closing the casing Once previous stages have been carried out, you can close the casing of the sigfox TEMP Procedure: Make sure that the seal is properly positioned on the base Clip the electronic board onto the casing’s base.
  • Page 72: Installation And Use

    TEMP- Guide utilisateur / User guide version V2.0.0 6. INSTALLATION AND USE 6.1. Correct positioning of the product transceivers There are two key rules for optimising radio ranges. • The first one consists of positioning your product as high as possible.
  • Page 73: Fixing With Screws

    TEMP- Guide utilisateur / User guide version V2.0.0 To optimise fastening onto a tube or mast, we recommend you Pins remove the Rail-DIN locking/unlocking lever. To remove it, pull the lever down until the locking pins are opposite Freed up part a freed-up part and then remove the lever 6.2.2 Fixing with screws...
  • Page 74: Din-Rail Fixing

    TEMP- Guide utilisateur / User guide version V2.0.0 6.2.3 DIN-Rail fixing This system, integrated into the casing, enables the product to be fastened onto a standard 35 mm rail. • To fit the casing, place the upper inserts on the rail and lower the product to clip it into position.
  • Page 75 TEMP- Guide utilisateur / User guide version V2.0.0 sigfox TEMP- Guide utilisateur / User guide version V2.0.0 DEUTSCH Vorschriften Page of 79...
  • Page 76: Technischer Support

    Recht vor, jederzeit und ohne Vorankündigung Änderungen an den Produktspezifi kationen und -beschreibungen vorzunehmen. adeunis® behält sich alle Rechte an diesem Dokument und den darin enthaltenen Informationen vor. Die Ver- vielfältigung, Nutzung oder Weiterverbreitung an Dritte ohne ausdrückliche Genehmigung ist streng untersagt.
  • Page 77 Programmiersprachen, unter Verwendung jeglicher elektrischer, mechanischer, magnetischer, optischer, manueller Geräte oder anderer Methoden, ist untersagt. adeunis® behält sich das Recht vor, ohne schriftliche Bekanntgabe und ohne ausdrückliches Verlangen seiner Kun- den die technischen Spezifi kationen oder Funktionen seiner Produkte zu ändern und sicherzustellen, dass die ihnen zur Verfügung gestellten Informationen gültig sind.
  • Page 78 TEMP- Guide utilisateur / User guide version V2.0.0 UMWELTSCHUTZHINWEISE Es wurden alle überfl üssigen Verpackungsmaterialien vermieden. Wir haben uns bemüht, dass die Verpackung leicht in drei Materialarten getrennt werden kann: Pappe (Schachtel), expandiertes Polystyrol (Puff ermaterial) und Polyethylen (Tüten, Schaumstoff -Schutzlage). Ihr Gerät besteht aus recycelbaren Materialien, die im Falle einer Demontage durch ein Fachunternehmen wiederverwendet werden können.
  • Page 79: Entsorgung Von Abfällen Durch Die Nutzer In Privathaushalten In Der Europäischen Union

    TEMP- Guide utilisateur / User guide version V2.0.0 sigfox TEMP- Guide utilisateur / User guide version V2.0.0 GEBRAUCHSHINWEISE • Überprüfen Sie vor Benutzung des Systems, ob die in dessen Betriebsanleitung angegebene Versorgungsspan- nung mit Ihrer Stromquelle übereinstimmt. Falls nicht, wenden Sie sich an Ihren Lieferanten.

Table des Matières