Flexible control
(NB: Only works with Electrolux heat pumps)
Once ControlBox24/7 has been set up for the correct heat pump model, you can control your heat pump by sending
text message to the unit. Follow the instructions below for giving the command. Please note that this command will
start the heat pump even when it is switched off.
The modes which can be selected on the heat pump are: HEAT, COOL and DRY.
To send a setting to the pump WITHOUT specifying a fan speed, enter the following:
<MODE><space><TEMPERATURE>
In the example above, the following setting is sent to the heat pump " Heat, 20°C, automatic fan speed"
An alternative to send to the heat pump is to state a specific fan speed by adding a colon after the temperature, and
then entering the desired fan speed. See the following:
<MODE><space><TEMPERATURE>:<FAN SPEED>
In the example above, the following setting is sent to the heat pump " Cool, 20°C, fan speed 2 ".
A list of the available
settings for the various
COOL
models is shown on
the right.
DRY
*DRY = non-adjustable
HEAT
fan speed.
Fan speed
Example: HEAT 20
Example: COOL 18:2
EHEAT
ECOOL
16-30
16-30
16-30 *
16-30 *
8, 16-30
8, 16-30
0 (auto), 1-5.
0 (auto), 1-5
13
REMOTE CONTROL YOUR HEAT PUMP
CHEAT
CCOOL
16-30 *
16-30 *
8, 16-30
8, 16-30
0 (auto), 1-3. 0 (auto), 1-3. 0 (auto), 1-3.
TIP! By sending the
OFF command, you can
also switch off the heat
pump.
HXHEAT
18-32