Low battery display:
If the battery power falls below a specified voltage, the message "Low batt" will appear and the
battery symbol will flash. To prevent a faulty test result, the tester will remain in this mode and
switch off automatically after 1 minute.
In this case, the battery must be replaced by a new, charged battery.
Technical data:
Measuring ranges:
Sensor lead length:
Dimensions, L x W x H:
Power supply:
Weight:
Specification:
1 EBT 03 (9 V battery not included)
1 Operating instructions
1 Display
2 Up button (ESC)
3 Down button
4 ON/OFF button
5 Sensor
6 Mark
130 °C to 260 °C, in steps of 2 °C,
from 0.1 % to 10 % in steps of 0.1 %
580 mm (with sensor)
150 x 85 x 40 mm
9 V-monobloc battery
200 g
1
2
3
4
5
6