Additional Cleaning Modes
Pulse Mode: The Pulse function creates a pulsating action by fluctuating the transducer power to
reduce standing waves.
This function helps spread the force of the standing waves making it safer to clean sensitive
objects, but we always suggest that when cleaning anything delicate to do a test run as some
damage still may occur.
Different Methods of Cleaning
General Cleaning: For lightly soiled objects you may need a cleaning solution at a low
concentrate of cleaning additive and for a short cycle, it is best to start at a 2-5 minute cycle and
increase strength as required dependant on the results achieved. reducing the generator/s power
setting is recommended, especially when cleaning delicate items. We suggest only using warm
water.
Enhanced Cleaning: If the objects in question need a deeper clean then we advise the use of an
ultrasonic cleaning solution mixed at a medium concentration and heated to the mid-range of the
fluids operating temperature.
Extensive Cleaning: Heavily soiled items should be cleaned with a steam cleaner or jet wash
to remove large heavy deposits or contaminants, failure to do this will prematurely contaminate
cleaning solutions and increase the cleaning cycle time requirements. For the removal of hard
or ingrained deposits, we recommend a pre-soaking in the ultrasonic bath with detergent/solvent
mixed to its strongest recommended concentration ratio to soften unwanted deposits whilst
heated to the high end of the fluids operating temperature range. Cleaning should be carried out
at the highest recommended fluid concentration and the highest recommended fluid temperature.
For more information on the range of RS Pros' range of solutions visit our website for the most
up to date range and pricing and availability.
www.rswww.com
Series Features
Timer, pulse, power and
on/off functions
Digital Display
10
ULTRASONIC CLEANER USER MANUAL
Stainless Steel Tank
Lockable wheels
www.rswww.com/- Images & Content @2013 RS Components Ltd
Temperature Dial