oPeratinG tHe Cleaner
Press the power button.
light should illuminate. If the light does not illuminate,
check the "troubleshooting" section for more details.
The steam cleaner should take between 3-6
minutes to heat up to steam temperatures, which
will be indicated when the green "steam ready"
indicator illuminates.
WARNING
!

refillinG water durinG oPeration

CAUTION
!
To avoid burn injury, do not refill clean water tank
before steamer has cooled completely. Use caution
when removing water fill safety cap. Even when
cap is able to be turned the steamer may still be
hot, especially all metal surfaces.
Turn power switch off and unplug cord.
Press down steam trigger (3.6,A) to release
pressure. When tank is under pressure, the
safety pressure indicator will rise above the
surface of the cap (3.7,B). When the tank is not
under pressure the safety pressure indicator will
be flush or below the surface (3.7,C).
Wait 7-10 minutes until the safety pressure
indicator has gone down, which indicates the
steamer has cooled. After 10 minutes, if the
safety pressure indicator has not fully dropped,
release residual steam pressure by pressing
trigger and then gently pushing the safety
pressure indicator. Slowly unscrew the water fill
safety cap counter-clockwise, but do not
remove. Allow machine to cool an additional 5
minutes. After you have ensured the steamer
has cooled and pressure has been released,
the water fill safety cap should turn freely for

after CleaninG

To avoid burn injury, do not refill clean water tank before steamer has cooled
completely. Use caution when removing water fill safety cap. Even when cap
is able to be turned the steamer may still be hot, especially all metal surfaces.

IMPORTANT

After the steamer is used, turn power off and then unplug the power cord.
Press down the steam trigger to release all pressure.
Wait 7-10 minutes until the safety pressure
cooled. After 10 minutes, if the safety pressure indicator has not fully dropped, release residual steam
pressure by pressing trigger and then gently pushing the safety pressure indicator. Slowly unscrew the
water fill safety cap counter-clockwise, but do not remove. Allow machine to cool an additional 5 minutes.
After you have ensured the steamer has cooled and pressure has been released, the water fill safety cap
should turn freely for removal. Unscrew the cap completely (3.9).
Empty the residual water in the tank and allow to dry. Clean the external
Re-install the water fill safety cap in a clockwise direction and tighten until completely sealed.
The blue power indicator
Do not operate unit
without
water
clean water tank.
!
CAUTION
!
Make sure safety cap is tightened securely before
continuing use or for storage.
to disinfect
To disinfect and kill 99.9% of harmful bacteria,
use steam cleaner without tools and attachments.
Fill the solution tank with the Hoover
Purpose Disinfectant as directed in "Removing and
Filling Solution Tank" section on page 6. Turn Clean
Control dial to HIGH. Hold steam nozzle 6-8" from
surface. Spray for 10 seconds and allow to sit for 1
minute.
in
3.6
removal. Unscrew the
water
fill
completely (3.8).
Remove any
water to avoid overfilling,
insert funnel and add
300ml clean water into
the measuring cup. Pour
the water into the tank
(3.8). (Max. capacity of
the tank is 300ml. Do not
overfill the tank to allow
space to be left at the top).
Re-install the water fill
direction and tighten until completely sealed.
!
indicator has gone down, which indicates the steamer has
7
3.7
A
3.8
safety
cap
remaining
safety cap in a clockwise
3.9
surface with a dry cloth.