IMPORTANT: The instruction manual you are holding includes essential information on the safety measures to be
implemented for installation and start-up. Therefore, the installer as well as the user must read the instructions before
beginning installation and start-up.
Keep this manual for future reference.
To achieve optimum performance of the HydroSpin Compact, follow the instructions provided below:
1. CONTENTS
Inside the box you will find the following components:
1.
HydroSpin Compact
2.
Multi-support
3.
Bag of accessories*
4.
Installation and maintenance manual
*Ball valve 3/4" Stainless Steel AISI 316, 2
connections for glueing Ø50 or screwing to 2
joints, 1 outlet elbow, 3 nuts and 3 anchor bolts.

2. GENERAL CHARACTERISTICS

The HydroSpin has been designed to work in all new and existing water installations.
Installing the HydroSpin in filtration systems from 3 to 16,5 m³/h and up to a maximum pressure of 2.5 bars is
recommended.
The HydroSpin:
 Significantly reduces water lost in drainage when cleaning the filters.
 Reduces the frequency with which the filtration system is cleaned.
The HydroSpin accumulates the separated solids in its lower part, which are then ejected by opening the purge
valve. This should be opened before the waste surpasses the limit indicated in Fig. 1 - pag.16.
3. INSTALLATION
The HydroSpin should be installed between the pump and the filter.
Ensure there is a drain in the area where the HydroSpin is located.
Ensure that the HydroSpin is installed on a horizontal surface.
There should be sufficient space around the HydroSpin to carry out
the inspections and maintenance that will be necessary during its
lifetime.
Wall installation:
1. Mark the three holes on the wall of the support.
2. Make the 3 Ø 8mm holes.
3. Screw in the support.
4. Position the Hydrospin Compact.
5. Join simple or 3 piece unions of Ø50 in the HydroSpin entrance
and exit.
6. Using valves in both the entrance and exit is recommended.
7. Thread the purge valve into the
lower part of the HydroSpin,
putting teflon in the thread.
Check that it is closed.
8. Join tubing from the HydroSpin
purge, to drainage (Fig. 2 -
pag.16).
9. Installation of a manometer in
the
HydroSpin
recommended. (Fig. 3 - pag.16).
10. Switch on the pump.
inlet
is
1
1/4"
, 2
2
4
2
3