Detection mode
The possibility of alternating between the two functioning methods is possible only with the use
of the HPSOFT software.
Detection mode NORMAL: as the term indicates, the barrier behaves as describes up to now,
generating the alarm when the signal drops below the sensitivity threshold line and this does not
coincide with the waveforms customised library, relating to possible "False alarms".
Detection mode ALARM IDENTIFY: the barrier will go in alarm only if the detected signal coincides
with one of those recorded in the waveforms customised library as "real alarm".
This detection mode can be used when wanting to detect only particular types of crossings. To
use this opportunity, carry out a series of passages to generate alarms. Once a sufficient number
of alarm signals have been caused, check the "events history" in barrier and transfer the alarm
signals on to the "real alarm" customised library.
The barrier will then generate the alarm only for signals similar to those saved in this library;
every other signal will not generate an alarm.
This solution can be of interest if wanting to detect only the transiting of heavy means (cars/
articulated lorries, etc.), but not the transiting of persons or other.
E

Synoptic panel

N
Access to this menu imposes to choose the type of connection; USB - PSTN/GSM.
For a connection in local it is necessary:
G
1- to power the barriers
2- to connect the barrier receiver to the computer using the USB connection.
note: if first connection, carry out the drivers loading procedure for the recognition of the peripheral.
3- to select the barrier address on HPSOFT and then choose "connect"
Once connected, it will be possible to display in real time, the information relating to all connected
barriers.
If we were connected to a barrier in USB its status would be verified, but if we were connected to
the serial satellite, we would be able to see the status of all active barriers in the system.
Displayed elements:
- Barrier's time and date settings
- power supply
- Test point
- Temperature in barrier
- Barrier status: Alarm - Tamper - Disqualification
- 58 -