Axis P7216 Guide D'installation page 14

Masquer les pouces Voir aussi pour P7216:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 19
AXIS P7216 Video Encoder
Function
Pin
1
0 V DC (-)
2
DC output
3–
Configurable
6
(Input or
Output)
RS485/422 Connector
Two 2-pin terminal blocks for RS485/RS422 serial
interface. The serial port can be configured to support:
• Two-wire RS485 half duplex
• Four-wire RS485 full duplex
• Two-wire RS422 simplex
• Four-wire RS422 full duplex point to point
communication
Function
RS485/RS422 RX/TX
A
RS485/RS422 RX/TX
B
RS485/RS422 TX A
RS485/RS422 TX B
Audio Connector
3.5 mm audio
connectors (stereo)
Notes
Can be used to power auxiliary equipment.
Note: This pin can only be used as power out.
Digital input – Connect to pin 1 to activate,
or leave floating (unconnected) to deactivate.
Digital output – Connected to pin 1 when
activated, floating (unconnected) when
deactivated. If used with an inductive load,
e.g. a relay, a diode must be connected in
parallel with the load, for protection against
voltage transients.
Pin
Notes
1
(RX) For full duplex RS485/RS422
(RX/TX) For half duplex RS485
2
3
(TX) For full duplex RS485/RS422
4
14
Specifications
0 V DC
3.3 V DC
Max load = 250 mA
0 to max 40 V DC
0 to max 40 V DC, open
drain, 100 mA

Publicité

Table des Matières
loading

Table des Matières