Facom 712B Notice D'instructions page 31

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 1
- Response: Average; calibrated to rms sine wave.
5.2.3 AC Current
Range
200A
600A
-
Frequency range: 45Hz~65Hz.
-
Max. input current: up to 600A for no more than 60
seconds.
-
Response: Average; calibrated to rms sine wave.
NOTE: Only when the current value is greater than 0.2A,
the meter will show its frequency value.
NOTE: When there is voltage or resistance detected in the
AC current shift, the LCD will display «Err».
5.2.4 DC Current
Range
200A
600A
- Max. input current: up to 600A for no more than 60
seconds.
NOTE: When there is voltage or resistance detected in the
AC current shift, the LCD will display «Err».
5.2.5 Resistance
Range
2KΩ
20KΩ
200KΩ
2MΩ
10MΩ
NU-712B_0618 7 langues.indd 31
Resolution
20A
0.01A
0.1A
Resolution
20A
0.01A
0.1A
Resolution
0.001KΩ
0.01KΩ
0.1KΩ
0.001MΩ
0.01MΩ
±(2.5% of reading + 8 digits)
1A
±(3.0% of reading +10 digits)
±(2.5% of reading + 8 digits)
1A
±(3.0% of reading +10 digits)
±(0.8% of reading + 3 digits)
±(1.0% of reading + 5 digits)
Accuracy
Accuracy
Accuracy