We are pleased that you decided
to buy a highly developed piece of
equipment from SCHICK and
would like to wish you every
success when working with your
new C2 Master motor unit.
We wrote these operating
instructions to enable you to get
accustomed to your new piece of
equipment and to provide you
with the correct operating and
maintenance instructions.
1.1 Ascertain that your mains supply coincides
with the data on the rating plate.
1.2 C2-Master - units are not suitable for the
following applications:
- in areas where there is a risk of explosion
- for medical applications
- for working on moist materials
1.3 Ensure that all regulatory requirements are
observed during use
- always wear protective glasses
- provide enough light at the working place
- use dust suction
1.4 Under no circumstances should the
motor handpiece be cleaned with
compressed air.
1.5 Before putting the handpiece down, always
insert a rotary instrument or the pin, supplied
with the unit, into chuck.
Caution:
- When using rotary instruments, do not
exceed the maximum speeds laid down by
their manufacturer.
- When operation with left-hand rotation, the
collet may loosen when there is a high load.
- Repairs and other technical procedures must
only be carried out by suitable qualified
personnel, authorized by SCHICK.
- SCHICK do not guarantee the C2 Master unit
should it not have been used in accordance
with the operating instructions.
Index

1. Safety information

Caution!
2. Range of applications
4. List of contents - accessoires
5. Setting up / operating the unit
6. Cruising System / digital display
9. Maintenance and care
2. Range of applications
The C2 Master unit is designed for universal use in
dental laboratories when trimming crowns and
bridges, respectively acrylic and light chrome cobalt
dentures.
With its speed range from 1.000 - 50.000 rpm the
SCHICK C2 Master - unit allows to work all dental
materials.
The motorhandpiece is ergonomical, small shaped
and runs smoothly, thus eliminating user-fatigue
and making it economical to use over long periods.
The progressive processor controller constantly
monitors the unit for overloading. A second
thermal fuse, which is independent of the
computer, provides further protection. Thus the
C2 Master - unit offers a maximum of safety.
Conditions of environment:
- interior 5° - 40° C.
- up to 2,000 meter over sea level
Categorie of overvoltage: II
Grade of pollution:
WEEE-Reg.-Nr. DE 78620387