7. Dual Blower screw mount locations.
M3.5 x 8 screws.
NOTE: To secure the 10" transition adapter to top of hood a cut out of 14 1/2" width x 10 1/2" depth will need
to be made in the cabinet bottom.
If internal cabinet dimensions prevent this size of a cut out then the 10" transition adapter may be mounted
to the cabinet bottom rather than the top of the hood. Cut out dimensions for this type of installation are
13 1/4" width x 6 1/4" depth.
8. Connect blower wire extrension cable from
PBD-1200A kit to new blower. Connect both
blower plugs.
14
www.zephyronline.com