Failure
BW 1000 PS does not switch on
Manual switch or fuse off
Daylight setting set on dark
Feed line interrupted
Detecting range adjusted incorrectly
Dirty lense
Light does not function although the BW 1000 PS switches
Incandescent lamp respectively
appliance faulty
Feed line interrupted
Light is on without interruption
Continous movement in the detecting
range
Manual switch on position "ON"
Undesired switching by itself
Switching on after power failure
Sunlight influence on the lense
Heat due to reflection from walls etc.
Trees moving in the wind causes the
switching
Heat changes because of extractor
hoods, kitchen window etc.
Inclusion of cars in large distance
Dogs or cats etc. are included in
short distance
Surch for defect
Remedy
Switching on
Adjust the settings
Check and repair
Control range, pass through detecting range,
control function, eventually by approaching
the hand
Please clean the lense
Changing of the lamp, respectively
appliance
Check and repair
Remove heat resource, wait until the
switching on for control the lense can be
covered. Adjust the BW 1000 PS again.
Put switch on position "OFF"
Normal case, light burns the adjusted time
Change brightness regulation or protect
BW 1000 PS against the sun
Change detecting range or cover the optics
partly
Change detecting range or cover the optics
partly
Change the mounting place
Reduce range (tilt angle) or cover the optics
for long distance range
Cover optics in the close range or change
detecting range